SERVICE MANUAL
© ISA, s.r.o. 2014-2015. All rights reserved.
We reserve the right to change the specification without prior notification.
Always check for new version of this document@
Service manual V1.08 | Nov-2015 | LM0002-EN
Page 20 of 97
220…415 V
220…240 V
380…415 V
Copper insulated cable
wire 2.5mm
2
R - Resistor 2200 Ω/ 4W
(optional accessory)
3.3
Basic setup
3.3.1
Overview
LVLØ controller needs basic information about the swimming pool which it is supposed to control. Knowing
how much water your pool will hold is the key to having the correct water chemistry and correct pool
operation.
3.3.2
Configuration
Basic setup has to be performed via LVLØ mobile application in Service section. After entering Service PIN,
click Basic setup.
Installation nr: <value> number of installation. Used in email notification, to identify device/customer. Best
practice is to use last 3 digits from serial number and store installation nr. in profile name too.
Pool volume: <value> value in m
3
. Setup the pool volume which will LVLØ operate. For details, please check
with your pool vendor if necessary. To calculate your swimming pool volume in cubic meters, follow the
following formula:
measure the length and width of the pool,
measure the depth of your pool,
multiply the result by the length and width of the pool
Pool mode, defines how LVLØ will operate the pool. It is possible to select from the following options:
In use: standard operation, water quality measurement, chemical dosing, filtration and all other
processes are in operation. Swimming pool water is maintained to be ready for use.
R