NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 27 - Electronic Control Schematic - Models MPI27 / MPI27CD
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de
cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
VALVE
BURNER & PILOT
ON/OFF
SWITCH
PILOT
ROOM AIR
BLOWER
BATTERY
HOLDER
ACCENT
LIGHT**
POWER
CORD
GRN
YLW
BLK
BRN
YLW
ORG
ORG
RED
BLK
WHT
BLK
WHT
GRN
GRN
YLW
ORG
WHT
GRN
WHT
BLU
BLU
BLK
1
4
PRG BUTTON
X6
X5
X4
X3
X2
X1
X10
X11
= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION
** Accent light not available for MPI27 or MPI27CD