10
Table 3-1
Description of acquisition frame parameters
Parameter
Description
SingleFrame
After starting acquisition, the camera only captures one image.
Continuous
After starting acquisition, the camera captures images consecutively.
When the number of acquisition lines reaches the height of the image, one
image will be generated, and then the images will be continuously generated in
this mode.
MultiFrame
Configure the frame rate (1–255) in
AcquisitionFrameCount
.
After starting acquisition, the camera captures images consecutively.
When the number of acquisition lines reaches the height of the image, one
image will be generated, and then the images will be continuously generated in
this mode, until the generated images reaches the value defined in
AcquisitionFrameCount
.
Trigger Mode
3.4
A line scan camera is generally triggered by line, frame, and line + frame. The trigger mode is
determined by
Trigger Selector
and
Trigger Mode
in
Acquisition Control
.
3.4.1
Trigger Type
Line trigger (
LineStart
): Outputs one line after receiving a trigger signal (rising edge or falling
edge), and outputs a frame of image when the received signals meet the defined image height.
Line trigger
Figure 3-8
Frame trigger (
FrameStart
): Outputs a frame of image after receiving a trigger signal (rising
edge or falling edge).
Frame trigger
Figure 3-9