3
Networking
Figure 1-3
Application Environment
1.4
Temperature and humidity.
The ambient temperature cannot exceed 50 °C, and it is best to for the camera to work in an
air-conditioned environment.
Ambient temperature when the camera is working: –30 °C to +50 °C.
Ambient humidity when the camera is working: 20%–80%, non-condensing.
Storage temperature: –30 °C to +80 °C.
Storage humidity: 20%–80%, non-condensing.
Install the device indoors and stably, and leave enough space for heat dissipation at four sides of
the device.
Certain air flow is required.
Status Indicator Lights
1.5
Table 1-1
Description of status indicator lights
Status
Indicator Status
Description
Normal
Red
Flashes quickly
Device starting.
Blue
Dim
The address has been allocated, and the
application software API is not connected to the
device.
Bright
The application software API is connected to the
device, free-run mode, no image transmission.
Flashes quickly
The application software API is connected to the
device, free-run mode, image transmission is
detected.
Flashes slowly
Trigger mode.
Red
Blue
Flashes
alternately
Firmware upgrading.
Abnormal Red
Solid
The device is abnormal, such as no bit stream,
firmware upgrade failure.
Flashes slowly
Network disconnected.