16
Similarly, when the image is stretched, you can adjust the divider value.
Adjustment results
Figure 3-20
Trigger Delay
3.5
Delay time can be set between the time that the camera receives trigger signal and the time that the
camera captures an image. The camera captures an image after the defined trigger delay.
Working principle of trigger delay
Figure 3-21
You can configure
Trigger Delay
. The unit is μs, and the range is 0 μs–10000000 μs, that is, 0 s–10 s.
Trigger delay
Figure 3-22
I/O Control
3.6
The external trigger input of the line scan camera supports three signal interfaces: Non-isolated
differential signal, non-isolated single-ended signal, and isolated single-ended signal.