18
MSK-101-POE | Advanced configuration manual v1.1 DEC 2019 | msk-101-poe_advanced-config_en_wo v1.1 | © 2019 Inxpect SpA
8. Fasten the sensor case to the bracket.
3.2.5 Direct the sensor
1. Turn the adjustable support to orient the
sensor direction vertically (barrier application)
or horizontally (volumetric application).
2. Tilt down the adjustable support to reach the
desired sensor inclination.
3.2.6 Access to the web interface
1. Check that the computer being used is
connected to the network where the sensor is
located.
2. Open a web browser.
Note
: to check the compatibility of the browser with
the web interface, visit the
www.inxpect.com/security/tools website.
3. Insert the following address into the address
bar:
If using...
Then type...
Windows via NetBIOS https://msk101poe-
xxxxx
OSX/Windows via
mDNS/Bonjour
https://msk101poe-
xxxxx.local
where "xxxxx" stands for the network (
NID
)
reported on the label on the case of the
sensor.
Note
: if a security warning appears or the sensor
cannot be reached, see "Web interface
troubleshooting" on page 25.
4. On the authentication page, insert the
password (default "admin") and then select
ENTER
: the first step of the first start-up
procedure appears.
5. If required, set a new password.
Note
: the password must contain at least 8
characters, of which at least one number, one
capital letter and one special character.
6. "Configure the sensor" below.
3.2.7 Configure the sensor
1. On the
Step 1: Sensor settings
page, if
necessary, change the country of installation.
Note
: correctly setting the country avoids violating
national restrictions on radio frequency allocation,
see "National restrictions" on page 29.
2. If other sensors are present in the area,
assign a specific channel to the sensor, or
select
None
.
3. Set the other parameters as desired.
4. Select
Save & Proceed
.
5. On the
Step 2: Installation
page, insert the
installation height. If the installation height
exceeds 3 m (11 ft), insert the height as 1 m (3
ft) (e.g. safeguarding for skylights or windows
in a warehouse).
6. Check that the detected direction
corresponds with the set direction and
compare the detected inclination with the
optimum recommended value. If necessary,
adjust the position of the adjustable support
accordingly.
7. Select
Save & Proceed
.
8. To guarantee the maximum detection
performance, on the
Step 3: Calibration
page, perform the calibration procedure (see
"Calibrate the sensor" on page 20).
9. On the
Step 4: Configuration
page, set the
alarm area and possible pre-alarm area.
3. Installation and use