MH860 series hydraulic servo drive
Operating through the LED panel
59
Code
Definition
Range
Default
Unit
protection
F089
Bus undervoltage
protection@
[0,1000]
380
V
F090
Bus undervoltage
protection @time
[0,30000]
150
5ms
F091
Bus undervoltage
protection
[0,1000]
320
V
F092
Bus undervoltage
protection for pipe
opening
[0,1000]
315
V
F093
AC overvoltage
protection@
[0,1000]
504
V
F094
AC overvoltage
protection @time
[0,30000]
300
5ms
F095
AC overvoltage
[0,1000]
1500
V
F096
AC undervoltage
protection@
[0,1000]
290
V
F097
AC undervoltage
protection @time
[0,30000]
101
5ms
F098
AC undervoltage
[0,1000]
0
V
F099
Power-on timeout
time
[0,30000]
2000
5ms
F100
Motor protection
temperature
[0,500]
125
℃
F101
Module protection
temperature
[0,500]
86
℃
F102
Air protection
temperature
[0,500]
400
℃
F103
Overcurrent protection
value
[0,900]
018→50
025→70
032→95
038→105
043→120
060→180
070→220
092→260
115→360
150→440
170→480
180→480
215→530
A
F104
Forward speed
protection value
[0,6000]
2700
rpm
F105
Reverse speed
protection value
[-6000,0]
-2700
rpm
F106
Overpressure
[0, 500]
195
bar