60
Range
- 0....999999999
Default
value
- 0
Comments
- Parameter enables addition of auxiliary identifier for heat
meter in telemetry system. The parameter is in no way
connected to real address of meter. The value of parameter is
stored in MT module and can be read from its memory map.
8.2.5.8. NMEA 0183 mode
Module MT-101 operating in
NMEA 0183
mode receives data from peripheral devices
using communication protocol compliant with NMEA 0183 at PORT2. The module
recognizes data received from AIRMAR weather station and places it in Internal registers.
Read more about NMEA 0183 mode...
8.2.5.8.1. Data validity time
Function
- Defines (in seconds) validity time of parameters read from
NMEA frames received at PORT2. When exceeded due to
incomplete reception, relevant bits signal that values in
registers are out of date. In other words, older than the time
declared in configuration.
Data type
- number
Range
- 1....300
Default
value
2
Comments
- n/a
8.2.5.9. FlexSerial
In
FlexSerial mode
MT-101 module can service units connected to PORT2 that employ
non standard protocols.
More about FlexSerial mode...
8.2.5.9.1. Max. length of data packet
Function
- defines (in bytes) max length of data packet in receiving
buffer.
Data type
- number
Range
- 1....512
Default
value
256
Comments
- none
8.2.5.9.2. Data packet delimiter
Function
- Defines (in seconds) interval between incoming bytes.
Exceeding this interval results in storing incomplete data
packet in receiving buffer
Data type
- number
Range
- 0,00....655,35 [s]
Default
value
1
[s]
Comments
- none