36
37
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Ventilation System iV-Twin+
•
Installation and Operating Instructions
Ventilation System iV-Twin+
•
Installation and Operating Instructions
7
Technical Specifications
7.1
General Specifications
Feature
Parameter
Operating temperature [°C]
-20 – 50
Exhaust air/external air
Without aggressive gases, dusts and
oils
Air volume flow in reversing operation [m³/h]
5 – 23
Exhaust air volume flow [m³/h]
10 – 45
Sound pressure level [dB (A)]
12 – 44
Standard sound level difference [dB]
45 – 56
Heat supply rate (η'
w
)
0.94
Input voltage [V DC]:
6 – 16
Power consumption [W]
0.5 – 3
Volume-flow-related electrical fan power [W/(m³/h)]
0.18
Safety class (DIN EN 61140)
III
Protection class (DIN EN 60529)
IPX4
Filter class Standard filter (DIN EN 779:2012)
G3
Antifreeze
Automatic by reversing operation (down
to -20 °C)
Weight [g]
7500
Conformity
Energy efficiency class
A+ / A
7.2
Energy label iV-Twin+ according to ErP directive, regulation 1254/2014
You will find the following information from the product data sheet on the energy label:
•
Energy efficiency class (SEC class)
• Sound power level L
wa
•
Maximum air volume flow (supply air)
2019
1254/2014
38
dB (A)
ENERGIA ·
ЕНЕРГИЯ
·
ΕΝΕΡΓΕΙΑ
· ENERGIJA · ENERGY · ENERGIE
· ENERGI
A
++
A
+
A
+++
A
++
A
+
A
-80%
A
-60%
A
-40%
A
-20%
A
+
A
B
C
D
E
F
G
23 m
3
/h
iV-Twin+
Demand-driven
Manually
controlled
MZ-Home
sMove with sensors
sMove without
sensors
A