30
31
CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE
Ventilation System iV-Twin+
•
Installation and Operating Instructions
Ventilation System iV-Twin+
•
Installation and Operating Instructions
6
Cleaning and Maintenance
CAUTION
Maintenance/cleaning by children and persons with limited abilities.
Injury to body parts and/or malfunction of the ventilation system!
• Do not have any cleaning or maintenance work on the ventilation system carried out by
children or persons who are unable to do so due to their physical, sensory or mental abilities,
inexperience or ignorance.
The iV-Twin+ ventilation system is virtually maintenance-free. The necessary cleaning and
maintenance work can be carried out by the user of the system himself after a short briefing.
TIP:
Disconnect the power supply to the ventilation system for cleaning and maintenance work,
and wear gloves.
Cleaning Agents
NOTE:
Owing to the scratch-sensitive plastic surface of the inner cover,
the surface may be damaged!
• Do not use cleaning agents containing sand, soda, acid or chlorine.
For cleaning, a commercially available detergent in warm water can be used. The following
tools can be used for cleaning:
• lint-free, soft cloth
• soft brush
• vacuum cleaner
Cleaning recommendations
The measures and intervals listed here are recommendations by inVENTer GmbH to maintain
the functionality and performance of the iV-Twin+ ventilation system.
Depending on requirements and/or air quality, your individual cleaning schedule may differ from
these recommendations.
Interval
Component
Cleaning action
Cleaning from inside
Monthly
Pollen filter
Replace the used filters.
Inner cover
Clean the surface of the cover with a damp cloth.
Quarterly
Dust filter
Wash the dust filters in warm water.
Or
Replace worn out dust filter.
Interval
Component
Cleaning action
Semi-annually
Heat accumulator
Remove the heat accumulator and clean it under
running hot water.
Fan unit
Clean the fan unit with a brush.
Activated carbon
filter
Replace the used filters.
Wall sleeve and
separators
Wipe the wall sleeve with a slightly damp cloth.
Leave the separating element in the wall sleeve.
Replace defective separators.
Base plate
Inner cover
Clean the surface of the base plate with a damp
cloth.
Cleaning from outside
Annually
External closure of
weather protection
hood
Clean the surface of the cover and the protective
grille at the outlet opening with a damp cloth.
6.1
Remove the cover of the inner cover.
To clean and check the components of the ventilation unit, first remove the cover of the inner
cover.
Prerequisite:
The ventilation unit is disconnected from the power
supply.
►
Open the inner cover (
►
Press the lateral latching lugs on the spacers of
the inner cover inwards.
►
Pull the inner cover cover forward.
Make sure
that all spacers disengage.
►
Remove the inner cover cover to the front.
You have removed the inner panel cover.
4 x CLICK