04/01/2015 Inventec Corp. Confidential 35
3.5.2.4.1.1. Socket 0/1 PcieDxxFx -Port xx
Aptio Setup Utility –Copyright © 2014 American Megatrends, Inc.
Main
Advanced
Server Mgmt Recovery Security Boot Save & Exit
Socket 0/1 PcieDxxFx -Portxx
----------------------------------------------------------
PCI-E Port
Hot Plug Capable
PCI-E Port Link
Link Speed
PCI-E Port DeEmphasis
PCI-E Port Link Status
PCI-E Port Link Speed
PCI-E Port L0s Exit Latency
PCI-E Port L1 Exit Latency
[Auto]
[Disable]
[Enable]
[Auto]
[-6.0 dB]
Link Did Not Train
Link Did Not Train
[4uS - 8uS]
[8uS - 16uS]
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.17.1245. Copyright © 2014 American Megatrends, Inc.
Menu Fields
Settings
Comments
Advanced\IIO Configuration\IIO0/1 Configuration\Socket 0/1 PcieDxxFx - Portxx
PCI-E Port
[Auto]
[Enable]
[Disable]
In auto mode the BIOS will remove the EXP port if
there is no device or errors on that device and the
device is not HP capable. Disable is used to disable
the port and hide its CFG space.
Hot Plug Capable
[Disable]
[Enable]
This option specifies if the link is considered Hot Plug
capable.
PCI-E Port Link
[Enable]
[Disable]
This option disables the link so that the no training
occurs but the CFG space is still active.
Link Speed
[Auto]
[Gen 1 (2.5 GT/s)]
[Gen 2 (5 GT/s)]
[Gen 3 (8 GT/s)]
PCI-E Port DeEmphasis
[-6.0 dB]
[-3.5 dB]
De-Emphasis control (LNKCON2[6]) for this PCIe port.
PCI-E Port L0s Exit Latency
[4uS - 8uS]
The length of time this port requires to complete
transition from L0s to L0
PCI-E Port L1 Exit Latency
[< 1uS]
[1uS - 2uS]
[2uS - 4uS]
The length of time this port requires to complete
transition from L1 to L0
Summary of Contents for N800G3
Page 1: ...P N 2015 MNU 000023 November 2015 Revision A 1U Server System User Manual N800G3 ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 20: ......
Page 32: ......
Page 59: ...Chapter 3 Connectors Backplane Connectors Power Distribution Board Connectors ...
Page 60: ......
Page 64: ......
Page 65: ...Chapter 4 Cable Routing ...
Page 66: ......
Page 67: ...Cable Routing 2015 MNU 000023 4 1 4 Cable Routing ...
Page 68: ......
Page 69: ...China RoHS Regulations Appendix ...
Page 70: ......
Page 71: ...Appendix 2015 MNU 000023 I Appendix China RoHS Regulations Figure I China RoHS Regulations ...
Page 72: ......
Page 73: ...Board Manual B800G3 June 2015 Revision A P N 2015 MNU 000009 ...
Page 75: ......
Page 80: ......
Page 90: ......
Page 98: ......
Page 100: ......
Page 112: ......
Page 132: ......
Page 133: ...Appendix China RoHS Regulations ...
Page 134: ......
Page 136: ...B800G3 BMC SPEC ...
Page 137: ...B800G3 BMC Specification Version 0 6 BMC Design Department IIA 2015 04 20 ...
Page 175: ...B800G3 BMC Specification 39 19 FIRMWARE UPDATE ...
Page 179: ...B800G3 BIOS SPEC ...
Page 180: ...04 01 2015 Inventec Corp Confidential 1 N800G3 BIOS Specification 04 01 2015 Version 1 0 ...
Page 215: ...04 01 2015 Inventec Corp Confidential 36 4uS 8uS 8uS 16uS 16uS 32uS 32uS 64uS 64uS ...