background image

citric

 

acid).

 

Don’t

 

scrub

 

with

 

aggressive

 

cleaning

 

products

 

because

 

this

 

might

 

etch

 

the

 

underlying

 

surface.

 

WHITE

 

FLAKES

 

IN

 

THE

 

WATER

 

•Excessive

 

calcium

 

hardness

 

is

 

   

present

 

in

 

pool

 

water.

     

 

   

Drain

 

about

 

20

 

to

 

25%

 

of

 

the

 

pool

 

water

 

and

 

add

 

fresh

 

water

 

to

 

decrease

 

the

 

calcium

 

hardness.

 

Inspect

 

the

 

   

electrolytic

 

cell

 

for

 

scale

 

buildup.

 

Clean

 

the

 

electrolytic

 

cell

 

if

 

necessary.

NO

 

LED

 

DISPLAY

 

   

No

 

power

 

supply.

 

 

RCD/GFCI

 

has

 

not

 

reseted.

 

•A

 

power

 

fuse

 

has

 

blown.

 

•LED

 

failure.

 

 

•Plug

 

the

 

cell

 

cord

 

firmly

 

into

 

the

 

cell

 

housing

 

receptacle.

 

 

Find

 

out

 

the

 

switch

 

and

 

turn

 

on.

 

   

Reset

 

the

 

RCD/GFCI.

 

   

Contact

 

Intex

 

Service

 

Center.

 

 

GREEN

 

HAIR

 

•High

 

copper

 

ion

 

concentration.

 

 

•Drain

 

20%

 

of

 

the

 

pool

 

water

 

and

 

add

 

fresh

 

water

 

to

 

decrease

 

the

 

copper

 

ion

 

concentration

 

below

 

0.3

 

ppm.

 

•Add

 

aluminum

 

sulfate:

 

1000

 

liters

 

water

 

need

 

around

 

2g

 

(1000

 

gals

 

need

 

0.27

 

ounce)

 

or

 

aluminum

 

potassium

 

sulfate:

 

1000

 

liters

 

water

 

need

 

around

 

3g

 

(1000

 

gals

 

need

 

0.4

 

ounce)

 

to

 

pool.

 

 

Use

 

‘Ultra

Swim’

 

shampoo,

 

or

 

shampoo

 

containing

 

chelating

 

agents.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(189PO)

   

MODEL

 

CS7111

   

SALTWATER

 

SYSTEM

 

&

 

FILTER

 

PUMP

   

ENGLISH

   

7.5”

 

X

 

10.3”

   

PANTONE

 

295U

   

07/31/2012

 

 

SAVE

 

THESE

 

INSTRUCTIONS

 

Page

 

25

 

English

 

TROUBLESHOOTING

 

GUIDE

 

(continued)

 

LED

 

PANEL

 

CODE

 

PROBLEM

   

SOLUTION

 

LED Panel Code Flash & Alarm On (NOTE

: Always turn off the power before cleaning and servicing).

90

 

1.Filter

 

pump

 

not

 

attached

 

to

 

system

 

and/or

 

switch

 

on

 

•Ensure

 

the

 

filter

 

pump

 

is

 

attached

 

and

 

operating.

   

See

 

“Setup

 

Instruction”

   

2.

 

Circulation

 

line

 

is

 

blocked.

 

 

•If

 

your

 

unit

 

has

 

plunger

 

valves,

 

ensure

 

that

 

they

 

are

 

open.

 

•Clear

 

your

 

filter

 

cartridge

 

and

 

cell

 

from

 

debris

 

and

 

dirt.

 

See

 

“Maintenance”.

 

•Release

 

all

 

trapped

 

air

 

in

 

the

 

circulation

 

line.

 

See

 

the

 

filter

 

pump

 

manual.

3.

 

Incorrect

 

inlet

 

and

 

outlet

 

hose

 

direction.

•Check

 

the

 

direction

 

of

 

the

 

inlet

 

and

 

the

 

outlet

 

hose.

 

Reverse

 

the

 

hoses

 

if

 

necessary.

 

See

 

“Set

 

Up

 

Instructions”.

4.

 

Scale

 

on

 

the

 

flow

 

sensor.

 

 

•Clean

 

the

 

flow

 

sensor,

 

paying

 

special

 

attention

 

to

 

the

 

hinge.

   

See

 

“Maintenance”.

 

5.

 

Flow

 

sensor

 

cord

 

is

 

loose.

 

 

   

Plug

 

the

 

flow

 

sensor

 

firmly

 

into

 

the

 

flow

   

 

sensor

 

receptacle.

 

6.

 

Inner

 

timer

 

confliction

 

between

 

   

filter

 

pump

 

and

 

saltwater

 

system.

   

Reset

 

both

 

timers

 

on

 

the

 

filter

 

pump

 

and

 

   

saltwater

 

system.

   

See

 

“Boost

 

Cycle”.

 

7.

 

Flow

 

sensor

 

failure.

 

   

Contact

 

Intex

 

Service

 

Center.

 

91

 

1.

 

Dirt

 

or

 

scale

 

on

 

titanium

 

plates.

   

Remove

 

the

 

electrolytic

 

cell

 

for

 

inspection.

 

Clean

 

it

 

if

 

necessary.

 

 

See

 

“Maintenance”.

2.

 

Low

 

salt

 

level

 

/

 

No

 

salt.

 

   

Add

 

salt.

 

See

 

“Salt

 

&

 

Pool

 

Water

 

Volumes”.

3.

 

Electrolytic

 

cell

 

cord

 

is

 

loose.

   

Ensure

 

that

 

the

 

cell

 

cord

 

is

 

plugged

 

firmly

 

into

 

the

 

cell

 

housing

 

receptacle.

Summary of Contents for CS7110

Page 1: ...PARTS WHEN SERVICING THIS PRODUCT IS FOR USE WITH STORABLE ABOVE GROUND POOLS ONLY DO NOT USE WITH PERMANENTLY INSTALLED POOLS CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 No 108 01 2012 Intex...

Page 2: ...only be used on this model of chlorine generating device Read the Label the Installation Manual and Operation Manual of the chlorine generating device Krystal Clear Saltwater System Model CS7110 befo...

Page 3: ...ust only be used on this model of copper ionization device Read the Label the Installation Manual and Operation Manual of the copper ionization device Krystal Clear Saltwater System Model CS7110 befor...

Page 4: ...Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed below IMPORTANT DO NOT RETURN PRODUCT TO STORE To purc...

Page 5: ...ol Water Volumes 13 Intex Pools Salt Table 14 Intex Pools Cyanuric Acid Table 15 Intex Pools Operating Time Table 16 Non Intex Pools Salt Table 17 Non Intex Pools Cyanuric Acid Table 17 Non Intex Pool...

Page 6: ...trician to replace the cord To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet...

Page 7: ...on has reached 0 2 0 3 ppm READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NUMBER 31003 PEST CONTROL PRODUCTS ACT Warning operating Krystal Clear Saltwater...

Page 8: ...SAVE THESE INSTRUCTIONS Page 5 English PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale...

Page 9: ...ound to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential...

Page 10: ...ITH THREADED COLLAR OPTIONAL 1 10849 2 O RING A 1 10712 3 SCREW 2 11519 4 ELECTROLYTIC CELL O RING C INCLUDED 1 11577 5 COPPER ELECTRODE 1 11579 6 TITANIUM ELECTRODE 1 11581 7 FLOW SENSOR 1 11460 8 CO...

Page 11: ...instantly starts destroying bacteria and algae It also oxidizes all other organic materials HOW COPPER IONS ARE GENERATED Low voltage direct current is applied to the copper electrode and copper ions...

Page 12: ...location extends the life of the titanium plates 1 Assemble the above ground pool AGP and its filter pump according to their installation instructions 2 Take the Saltwater System and its accessories o...

Page 13: ...e saltwater pool system 2 Connect the adaptor A 1 to the electrolytic cell 4 outlet as shown in Drawing 1 Tighten securely 3 Disconnect the water return hose from the filter pump connection and connec...

Page 14: ...ns do not require the adaptors A 1 or B 9 Install as follows Drawing 2 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves before inst...

Page 15: ...connector hose 8 to the filter pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Saltwater System to the pump co...

Page 16: ...st due to evaporation Adding Salt 1 Switch the filter pump on to start water circulation 2 Keep the saltwater system turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly sprea...

Page 17: ...10 50 30 15 488cm x 132cm 16 x52 4614 17464 115 50 30 15 549cm x 107cm 18 x42 4786 18115 120 55 30 15 549cm x 122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12...

Page 18: ...0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cm x 84cm 15 x33 2587 9792 0 6 0 3 457cm x 91cm 15 x36 2822 10681 0 7 0 3 457cm x 107cm 15 x42 3284 12430 0 8 0 4 457...

Page 19: ...86 18115 5 5 6 8 549cm x 122cm 18 x48 5455 20647 6 6 7 8 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12422 3 4 5 6 457cm x 107cm 15 x42 3861 14614 4 4 5 6 457cm x 122cm 15 x48 4440 16805 5 5 6...

Page 20: ...N NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 CYA...

Page 21: ...filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the saltwater system and finishing 15 minutes after the saltwater syste...

Page 22: ...e maximum pool volume of 26000L it will take from approximately 2 days for the copper concentration to reach the recommended level when the system is set at its maximal intensity Maintain 1 3ppm of fr...

Page 23: ...ing Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code...

Page 24: ...the pool water is hard high mineral content the cell may require periodic manual cleaning To maintain maximum performance we recommend that you open and visually inspect the electrolytic cell once ev...

Page 25: ...he copper concentration has reached 0 2 0 3 ppm Directions and Use 1 Dip the entire strip into the water and remove immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the...

Page 26: ...ion Low alkalinity will cause the pH to be unstable Any chemical added to the water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficien...

Page 27: ...e water using the test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running INSUFFICIENT COPPER ION LEVEL Insufficient operating hours The...

Page 28: ...continued LED PANEL CODE PROBLEM SOLUTION LED Panel Code Flash Alarm On NOTE Always turn off the power before cleaning and servicing 90 1 Filter pump not attached to system and or switch on Ensure th...