background image

 
 
 
 
 
 

   

 

(189PO)

   

MODEL

 

CS7111

   

SALTWATER

 

SYSTEM

 

&

 

FILTER

 

PUMP

   

ENGLISH

   

7.5”

 

X

 

10.3”

   

PANTONE

 

295U

   

07/31/2012

 

Page

 

17

 

English

 

SAVE

 

THESE

 

INSTRUCTIONS

 

SALT

 

CALCULATION

 

FORMULA

 

FOR

 

ALL

 

POOLS

 

Salt

 

Needed

 

for

 

Startup

 

(Lbs)

 

Salt

 

Needed

 

for

 

Startup

 

(Kgs)

 

Salt

 

Needed

 

when

 

Low

 

Salt

 

Detected

 

(Lbs)

 

Salt

 

Needed

 

when

 

Low

 

Salt

 

Detected

 

(Kgs)

 

Water

 

Capacity

 

(Gals)

 

x

 

0.025

 

Water

 

Capacity

(Liters)

 

x

 

0.003

 

Water

 

Capacity

(Gals)

 

x

 

0.0067

 

Water

 

Capacity

 

(Liters)

 

x

 

0.0008

 

 

SALT

 

TABLE

 

FOR

 

COMMON

 

NON

INTEX

 

POOLS

 

Water

 

Capacity

 

Salt

 

Needed

 

for

 

Startup

Salt

 

Needed

 

when

 

Low

 

Salt

 

Detected

 

(CODE

 

“91”)

 

Gals

 

Liters

 

Lbs

 

Kgs

Lbs

Kgs

 

2000

 

7500

 

50

 

20

 

10

 

5

 

4000

 

15000

 

100

 

45

 

25

 

10

 

6000

 

22500

 

150

 

65

 

40

 

20

 

 

CYANURIC

 

ACID

 

TABLE

 

FOR

 

COMMON

 

NON

INTEX

 

POOLS

 

Water Capacity 

Cyanuric

 

Acid

 

Needed

 

for

 

Startup

 

0.03g/L

 

(30ppm)

 

Gals Liters  Lbs  Kgs 

2000 7500  0.50 0.23 
4000 1500  1.00 0.45 
6000 22500  1.50  0.68 

 

 

OPERATING

 

TIME

 

TABLE

 

FOR

 

COMMON

 

NON

INTEX

 

POOLS

 

(WITH

 

CYANURIC

 

ACID)

 

Water Capacity

 

Operating

 

Time

 

(hours)

at

 

different

 

ambient/air

 

temperatures

 

Gals Liters 

10 

– 

19

o

(50 – 66

o

F) 

20-28

o

(68-82

o

F) 

29-36

o

(84-97

o

F) 

2000 7500  2 

2  3 

4000 15000  4 

5  6 

6000 22500  7 

7  8 

 

 

Summary of Contents for CS7110

Page 1: ...PARTS WHEN SERVICING THIS PRODUCT IS FOR USE WITH STORABLE ABOVE GROUND POOLS ONLY DO NOT USE WITH PERMANENTLY INSTALLED POOLS CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 No 108 01 2012 Intex...

Page 2: ...only be used on this model of chlorine generating device Read the Label the Installation Manual and Operation Manual of the chlorine generating device Krystal Clear Saltwater System Model CS7110 befo...

Page 3: ...ust only be used on this model of copper ionization device Read the Label the Installation Manual and Operation Manual of the copper ionization device Krystal Clear Saltwater System Model CS7110 befor...

Page 4: ...Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed below IMPORTANT DO NOT RETURN PRODUCT TO STORE To purc...

Page 5: ...ol Water Volumes 13 Intex Pools Salt Table 14 Intex Pools Cyanuric Acid Table 15 Intex Pools Operating Time Table 16 Non Intex Pools Salt Table 17 Non Intex Pools Cyanuric Acid Table 17 Non Intex Pool...

Page 6: ...trician to replace the cord To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet...

Page 7: ...on has reached 0 2 0 3 ppm READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NUMBER 31003 PEST CONTROL PRODUCTS ACT Warning operating Krystal Clear Saltwater...

Page 8: ...SAVE THESE INSTRUCTIONS Page 5 English PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale...

Page 9: ...ound to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential...

Page 10: ...ITH THREADED COLLAR OPTIONAL 1 10849 2 O RING A 1 10712 3 SCREW 2 11519 4 ELECTROLYTIC CELL O RING C INCLUDED 1 11577 5 COPPER ELECTRODE 1 11579 6 TITANIUM ELECTRODE 1 11581 7 FLOW SENSOR 1 11460 8 CO...

Page 11: ...instantly starts destroying bacteria and algae It also oxidizes all other organic materials HOW COPPER IONS ARE GENERATED Low voltage direct current is applied to the copper electrode and copper ions...

Page 12: ...location extends the life of the titanium plates 1 Assemble the above ground pool AGP and its filter pump according to their installation instructions 2 Take the Saltwater System and its accessories o...

Page 13: ...e saltwater pool system 2 Connect the adaptor A 1 to the electrolytic cell 4 outlet as shown in Drawing 1 Tighten securely 3 Disconnect the water return hose from the filter pump connection and connec...

Page 14: ...ns do not require the adaptors A 1 or B 9 Install as follows Drawing 2 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves before inst...

Page 15: ...connector hose 8 to the filter pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Saltwater System to the pump co...

Page 16: ...st due to evaporation Adding Salt 1 Switch the filter pump on to start water circulation 2 Keep the saltwater system turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly sprea...

Page 17: ...10 50 30 15 488cm x 132cm 16 x52 4614 17464 115 50 30 15 549cm x 107cm 18 x42 4786 18115 120 55 30 15 549cm x 122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12...

Page 18: ...0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cm x 84cm 15 x33 2587 9792 0 6 0 3 457cm x 91cm 15 x36 2822 10681 0 7 0 3 457cm x 107cm 15 x42 3284 12430 0 8 0 4 457...

Page 19: ...86 18115 5 5 6 8 549cm x 122cm 18 x48 5455 20647 6 6 7 8 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12422 3 4 5 6 457cm x 107cm 15 x42 3861 14614 4 4 5 6 457cm x 122cm 15 x48 4440 16805 5 5 6...

Page 20: ...N NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 CYA...

Page 21: ...filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the saltwater system and finishing 15 minutes after the saltwater syste...

Page 22: ...e maximum pool volume of 26000L it will take from approximately 2 days for the copper concentration to reach the recommended level when the system is set at its maximal intensity Maintain 1 3ppm of fr...

Page 23: ...ing Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code...

Page 24: ...the pool water is hard high mineral content the cell may require periodic manual cleaning To maintain maximum performance we recommend that you open and visually inspect the electrolytic cell once ev...

Page 25: ...he copper concentration has reached 0 2 0 3 ppm Directions and Use 1 Dip the entire strip into the water and remove immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the...

Page 26: ...ion Low alkalinity will cause the pH to be unstable Any chemical added to the water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficien...

Page 27: ...e water using the test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running INSUFFICIENT COPPER ION LEVEL Insufficient operating hours The...

Page 28: ...continued LED PANEL CODE PROBLEM SOLUTION LED Panel Code Flash Alarm On NOTE Always turn off the power before cleaning and servicing 90 1 Filter pump not attached to system and or switch on Ensure th...

Page 29: ...warnings instructions and safety guidelines cover some common risks of water recreation but do not cover all risks and dangers For additional safeguards also familiarize yourself with the following g...

Page 30: ...al retail purchase Keep your original sales receipt with this manual as proof of purchase will be required and must accompany warranty claims or the Limited Warranty is invalid Krystal Clear Saltwater...

Page 31: ...ect to negligence abnormal use or operation accident improper operation improper voltage or current contrary to operating instructions or to damage by circumstances beyond Intex s control including bu...