(188PO)  MODEL CS7110  SALTWATER SYSTEM  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/10/2012 

Page 12 
English 

    SAVE THESE INSTRUCTIONS

 

 

SETUP

 

INSTRUCTIONS

 

(continued)

 

Connecting

 

the

 

system

 

to

 

other

 

types

 

of

 

pump

 

(with

 

different

 

type

 

of

 

thread

 

or

 

no

 

thread):

 

The

 

Saltwater

 

System

 

can

 

also

 

be

 

adapted

 

to

 

other

 

filter

 

pumps

 

with

 

different

 

thread

 

or

 

those

 

without

 

a

 

thread

 

on

 

the

 

connection.

 

 

Connection

 

to

 

1

1/4”

 

(32mm)

 

hose:

 

1.Connect

 

one

 

end

 

of

 

adaptor

 

B(9)

 

to

 

the

 

connector

 

hose(8).

 

Tighten

 

securely.

 

2.Now,

 

connect

 

the

 

other

 

end

 

of

 

adaptor

 

B(9)

 

to

 

the

 

filter

 

pump

 

outlet.

 

Tighten

     

securely.

 

 
 
 
 

Connection

 

to

 

1

1/2”

 

(38mm)

 

hose

 

with

 

clamp:

 

1.Connect

 

the

 

connector

 

hose

 

(8)

 

to

 

the

 

filter

 

pump

 

outlet

 

connection

 

with

 

a

 

large

     

hose

 

clamp.

 

Tighten

 

securely

 

 
 
 

Connecting the system to other types of pool

 

After you have connected the Saltwater System to the pump, connect it to 
the pool. This is depicted in Drawings #1 and #2. 
Following are the common connection types: 

 
 
 
 
 
 
Connection to 1-1/4” (32mm) connectors:

 

1.

  Connect the adaptor A

(1)

 to the electrolytic cell

(4)

 outlet. Tighten securely. 

2.

  The adapter A

(1)

 is now fitted to the Saltwater System. The following step is to     

connect the water return hose to the adaptor A

(1)

 with a hose clamp. 

 
 
 
 
 
 
 
Connection to 1-1/2” (38mm) connectors without thread:

 

1.

  Connect the adaptor A

(1)

 to the electrolytic cell

(4)

 outlet. Tighten securely. 

2.

  With the adaptor A

(1)

 fixed to the Saltwater System, connect the water return     

hose to the adaptor, using a large hose clamp.

Summary of Contents for CS7110

Page 1: ...PARTS WHEN SERVICING THIS PRODUCT IS FOR USE WITH STORABLE ABOVE GROUND POOLS ONLY DO NOT USE WITH PERMANENTLY INSTALLED POOLS CONFORMS TO UL STD 1081 CERTIFIED TO CSA STD C22 2 No 108 01 2012 Intex...

Page 2: ...only be used on this model of chlorine generating device Read the Label the Installation Manual and Operation Manual of the chlorine generating device Krystal Clear Saltwater System Model CS7110 befo...

Page 3: ...ust only be used on this model of copper ionization device Read the Label the Installation Manual and Operation Manual of the copper ionization device Krystal Clear Saltwater System Model CS7110 befor...

Page 4: ...Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed below IMPORTANT DO NOT RETURN PRODUCT TO STORE To purc...

Page 5: ...ol Water Volumes 13 Intex Pools Salt Table 14 Intex Pools Cyanuric Acid Table 15 Intex Pools Operating Time Table 16 Non Intex Pools Salt Table 17 Non Intex Pools Cyanuric Acid Table 17 Non Intex Pool...

Page 6: ...trician to replace the cord To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet...

Page 7: ...on has reached 0 2 0 3 ppm READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NUMBER 31003 PEST CONTROL PRODUCTS ACT Warning operating Krystal Clear Saltwater...

Page 8: ...SAVE THESE INSTRUCTIONS Page 5 English PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale...

Page 9: ...ound to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential...

Page 10: ...ITH THREADED COLLAR OPTIONAL 1 10849 2 O RING A 1 10712 3 SCREW 2 11519 4 ELECTROLYTIC CELL O RING C INCLUDED 1 11577 5 COPPER ELECTRODE 1 11579 6 TITANIUM ELECTRODE 1 11581 7 FLOW SENSOR 1 11460 8 CO...

Page 11: ...instantly starts destroying bacteria and algae It also oxidizes all other organic materials HOW COPPER IONS ARE GENERATED Low voltage direct current is applied to the copper electrode and copper ions...

Page 12: ...location extends the life of the titanium plates 1 Assemble the above ground pool AGP and its filter pump according to their installation instructions 2 Take the Saltwater System and its accessories o...

Page 13: ...e saltwater pool system 2 Connect the adaptor A 1 to the electrolytic cell 4 outlet as shown in Drawing 1 Tighten securely 3 Disconnect the water return hose from the filter pump connection and connec...

Page 14: ...ns do not require the adaptors A 1 or B 9 Install as follows Drawing 2 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves before inst...

Page 15: ...connector hose 8 to the filter pump outlet connection with a large hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Saltwater System to the pump co...

Page 16: ...st due to evaporation Adding Salt 1 Switch the filter pump on to start water circulation 2 Keep the saltwater system turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly sprea...

Page 17: ...10 50 30 15 488cm x 132cm 16 x52 4614 17464 115 50 30 15 549cm x 107cm 18 x42 4786 18115 120 55 30 15 549cm x 122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12...

Page 18: ...0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cm x 84cm 15 x33 2587 9792 0 6 0 3 457cm x 91cm 15 x36 2822 10681 0 7 0 3 457cm x 107cm 15 x42 3284 12430 0 8 0 4 457...

Page 19: ...86 18115 5 5 6 8 549cm x 122cm 18 x48 5455 20647 6 6 7 8 CIRCULAR METAL FRAME POOL 457cm x 91cm 15 x36 3282 12422 3 4 5 6 457cm x 107cm 15 x42 3861 14614 4 4 5 6 457cm x 122cm 15 x48 4440 16805 5 5 6...

Page 20: ...N NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 CYA...

Page 21: ...filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the saltwater system and finishing 15 minutes after the saltwater syste...

Page 22: ...e maximum pool volume of 26000L it will take from approximately 2 days for the copper concentration to reach the recommended level when the system is set at its maximal intensity Maintain 1 3ppm of fr...

Page 23: ...ing Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code...

Page 24: ...the pool water is hard high mineral content the cell may require periodic manual cleaning To maintain maximum performance we recommend that you open and visually inspect the electrolytic cell once ev...

Page 25: ...he copper concentration has reached 0 2 0 3 ppm Directions and Use 1 Dip the entire strip into the water and remove immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the...

Page 26: ...ion Low alkalinity will cause the pH to be unstable Any chemical added to the water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficien...

Page 27: ...e water using the test strips If the pool is clean and clear add stabilizer to the water and then test the water with the device running INSUFFICIENT COPPER ION LEVEL Insufficient operating hours The...

Page 28: ...continued LED PANEL CODE PROBLEM SOLUTION LED Panel Code Flash Alarm On NOTE Always turn off the power before cleaning and servicing 90 1 Filter pump not attached to system and or switch on Ensure th...

Page 29: ...warnings instructions and safety guidelines cover some common risks of water recreation but do not cover all risks and dangers For additional safeguards also familiarize yourself with the following g...

Page 30: ...al retail purchase Keep your original sales receipt with this manual as proof of purchase will be required and must accompany warranty claims or the Limited Warranty is invalid Krystal Clear Saltwater...

Page 31: ...ect to negligence abnormal use or operation accident improper operation improper voltage or current contrary to operating instructions or to damage by circumstances beyond Intex s control including bu...

Reviews: