Intertek MES80 Installation Instructions Manual Download Page 33

33

Blower Performance Data

MES80

0.1

Rise

0.2

Rise

0.3

Rise 0.4 Rise

0.5

Rise

0.6

0.7

0.8

Blue

789

38

735

40

676

44

625

47

588

50

545

500

437

Red

1209

25

1141

26

1094

27

1048

28

1004

30

968

927

890

Orange

696

43

556

53

494

NA

436

NA

377

NA

298

238

189

Black

728

41

669

44

612

48

564

53

514

NA

464 417 337

Brown

982

30

928

32

877

34

830

36

782

38

740 724

680

Blue

1309

34

1274

35

1242

36

1211

37

1180

38

1146 1117

1090

Red

1120

40

1097

41

1059

42

1023

43

989

45

953

919 885

Orange

708

NA

550

NA

501

NA

449

NA

389

NA

324 276 231

Black

713

NA

665

NA

607

NA

558

NA

508

NA

462 412 351

Brown

987

45

920

48

874

NA

852

NA

807

NA

770 733

692

Blue

1339

33

1279

35

1226

36

1175

38

1128

39

1081

1032 983

Red

1828

24

1780

25

1738

26

1697

26

1663

27

1620 1588

1546

Orange

898

49

794

NA

723

NA

656

NA

588

NA

522

449 384

Black

1443

31

1388

32

1339

33

1292

34

1242

36

1202 1155

1107

Brown

1601

28

1559

29

1513

29

1473

30

1413

31

1405 1365 1325

Blue

1280

46

1249

47

1201

49

1159

51

1116

53

1073 1032 994

Red

1743

NA

1703

35

1686

35

1669

36

1640

36

1608

1576 1543

Orange

845

NA

664

NA

596

NA

525

NA

456

NA

381 318 257

Black

1370

43

1352

44

1310

45

1269

47

1226

48

1186

1145 1107

Brown

1537

39

1498

40

1483

40

1450

41

1425

42

1389 1345 1313

Blue

1344

44

1273

47

1217

49

1148

52

1093

54

1029

972

910

Red

2297

NA

2240

NA

2189

NA

2142

NA 2105

NA

2063 2027

1990

Orange

1469

40

1415

42

1359

44

1305

45

1248

47

1194 1135 1083

Black

1672

35

1605

37

1543

38

1488

40

1453

41

1403 1351 1301

Brown

1899

NA

1840

NA

1784

NA

1731

NA

1687

35

1642 1597

1550

*MES800805CU

Wire Color

*MES800403AU

CFM - EXTERNAL STATIC PRESSURE (Inches w.c.)

*MES800603AU

*MES800604BU

*MES800804BU

*

*

*Cooling Only

Summary of Contents for MES80

Page 1: ...ION 6 LOCATION REQUIREMENTS AND CONSIDERATIONS 7 Clearances and Accessibility 8 Installation Positions 8 Venting For Horizontal Left Or Right Installations 8 Horizontal Installation 8 Furnace Suspensi...

Page 2: ...ustment 23 Gas Input Rate Measurement Natural Gas Only 23 Temperature Rise 24 Circulator Blower Fan Timing Adjustment 24 OPERATIONAL CHECKS 25 Checking Duct Static 25 SAFETY CIRCUIT DESCRIPTION 25 Gen...

Page 3: ...ce qui peut entra ner la mort des blessures ou des dommages mat riels IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL I...

Page 4: ...nt pas suivies pour chacun des appareils raccord s au syst me de ventilation au moment de sa mise en marche cela peut entra ner une intoxication au monoxyde de carbone ou la mort Les tapes suivantes d...

Page 5: ...ing precautions during furnace installation and servicing to protect the integrated control module from damage By putting the furnace the control and the person at the same electrostatic potential the...

Page 6: ...furnace A return air temperature range between 60 F 16 C and 80 F 27 C is maintained Air filters are installed in the system and replaced daily during construction and upon completion of construction...

Page 7: ...icals halogen type refrigerants printing inks cleaning solutions such as perchloroethylene paint removers varnishes hydrochloric acid cements and glues antistatic fabric softeners for clothes dryers m...

Page 8: ...gas electrical and drain line connections NOTE In addition to the required clearances to combustible materials a minimum of 24 service clearance must be available in front of the unit Installation Po...

Page 9: ...ndition c In so far as practical close all building doors and windows and all doors between the space in which the appliance s connected to the venting system are located and other spaces of the build...

Page 10: ...oset or utility room must have two ventilation openings with a total minimum free area of 0 25 square inches per 1 000 BTU hr of furnace input rating Refer to Specification Sheet applicable to your mo...

Page 11: ...PPED APPLIANCE THE POTENTIAL FOR CONDENSATION DAMAGE MAY STILL EXIST WITH EXTREMELY COLD CONDITIONS LONG VENT CONNECTORS EXTERIOR CHIMNEYS OR ANY COMBINATION OF THESE CONDITIONS THE RISK OF CONDENSATI...

Page 12: ...existing metal liners are correctly installed and in good condition Remove the lowest existing vent connector and examine the inside of the elbow or tee at the base of the liner A small amount of soo...

Page 13: ...y recognized building codes or standards One such standard which may be referenced is the Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances ANSI NFPA 211 Remember that all appli...

Page 14: ...or thimbles must be used to prevent the B vent from coming into direct contact with the tile liner or chimney walls Direct contact would result in higher heat loss with an increased possibility of poo...

Page 15: ...s or by the rotation of the fan Also confirm that wiring location will not interfere with fil ter removal or other maintenance After the junction box is in the desired location use washers to connect...

Page 16: ...p in a fossil fuel application A fossil fuel application refers to a combined gas furnace and heat pump installation which uses an outdoor temperature sensor to determine the most cost efficient means...

Page 17: ...f old pipe is used be sure it is clean and free of rust scale burrs chips and old pipe joint compound Use pipe joint compound on male threads ONLY Always use pipe joint compound pipe dope that is APPR...

Page 18: ...size that the heat exchanger can be viewed for visual light inspection or such that a sampling probe can be inserted into the airstream The access panel must be made to prevent air leaks when the furn...

Page 19: ...be installed in the central return register or a side panel external filter rack kit upflows As an alternative a media air filter or electronic air cleaner can be used as the primary filter The follo...

Page 20: ...have 5 media filters and are available in the following configurations Consult your distributor for information on our complete line of IAQ Clean Comfort products Air cleaner installation location Ma...

Page 21: ...call for fan Circulator blower is de energized Electronic air cleaner terminals are de energized Furnace awaits the next call from thermostat Start up Procedure And Adjustment Furnace must have a 120...

Page 22: ...stem 3 Inlet pressure tap connections a White Rodgers valve Back inlet pressure test screw inlet pressure tap out one turn counterclockwise not more than one turn 4 Connect calibrated U tube manometer...

Page 23: ...regulator cover screw 10 Turn OFF all electrical power and gas supply to the system 11 Remove the manometer hose from the hose barb fitting or outlet pressure Tap 12 Replace outlet pressure tap a Whit...

Page 24: ...onvert capacity to tons Example Cooling Capacity of 30 000 BTU hr 30 000 12 000 2 5 Tons 2 Determine the proper air flow for the cooling system Most cooling systems are designed to work with air volum...

Page 25: ...Operational Checks TO AVOID PERSONAL INJURY OR DEATH DO NOT REMOVE ANY INTERNAL COMPARTMENT COVERS OR ATTEMPT ANY ADJUSTMENT ELECTRICAL COMPONENTS ARE CONTAINED IN BOTH COMPARTMENTS CONTACT A QUALIFIE...

Page 26: ...ure activated sensor It guards against overheating resulting from insufficient air passing over the heat exchanger The auxiliary limit control is suitable for both horizontal right and horizontal left...

Page 27: ...Y OR DEATH DISCONNECT ELECTRICAL POWER BEFORE REMOVING FILTERS NEVER OPERATE FURNACE WITHOUT A FILTER INSTALLED BECAUSE DUST AND LINT WILL BUILD UP ON INTERNAL PARTS RESULTING IN LOSS OF EFFICIENCY EQ...

Page 28: ...lthough only functional parts are shown in the parts list all sheet metal parts doors etc may be ordered by description Parts are available from your distributor Functional Parts List Gas Valve Natura...

Page 29: ...10 Integrated Control Module 11 Transformer 12 Blower Door Interlock Switch 13 Circulator Blower Component ID Tubular Heat Exchanger Pressure Sensor Assembly Flue Pipe Connection Gas Line Entrance Ga...

Page 30: ...in Electrostatic Discharge section of manual Furnace Fails to operate Control LED is flashing TWO 2 RED flashes 2 Flashes RED Pressure sensor indicates pressure reading when it should be zero Faulty...

Page 31: ...ockage or excessive wear and replace as needed Check and correct pressure sensor wiring Turn power OFF prior to repair Replace induced draft blower with proper replacement part LED is steady on Steady...

Page 32: ...combustion noise during heating Insufficient combustion air or high input Blocked flue and or air inlet pipe or faulty induced draft blower or pressure sensor Check and correct gas supply and manifol...

Page 33: ...7 26 1663 27 1620 1588 1546 Orange 898 49 794 NA 723 NA 656 NA 588 NA 522 449 384 Black 1443 31 1388 32 1339 33 1292 34 1242 36 1202 1155 1107 Brown 1601 28 1559 29 1513 29 1473 30 1413 31 1405 1365 1...

Page 34: ...D JUNCTION INTEGRATED CONTROL INTERNAL TO 0140F02416 A 2 MANUFACTUR S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS NOTES HI VOLTAGE FIE...

Page 35: ...35 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 36: ...ering your product is a relatively short process and entitles you to additional warranty protection except that failure by California and Quebec residents to register their product does not diminish t...

Reviews: