background image

www.intertec.info

Operating Instructions SL MULTITHERM D.A

Page 8 / 8

HOM499575435Ien-6

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

NOTICE

Environmental damage may be caused if dis-
posed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be dis-
posed of by certified specialists!

The  local  community  authorities  or  specialist  waste  dis-
posal  companies  can  provide  information  on  environ-
mentally friendly disposal.

14

EU declaration of conformity

The  manufacturer,  INTERTEC-Hess  GmbH,  Raffiner-
iestrasse  8,  93333  Neustadt/Donau,  Germany,  hereby
declares in sole responsibility that the product

Product / Type designation:

SL MULTITHERM

complies  with  the  provisions  of  the  following  directives
2014/34/EU  (ATEX),  2014/30/EU  (EMC),  2011/65/EU
(RoHS), 2012/19/EU (WEEE) complies with the following
standards,  harmonized  standards,  where  appropriate
and/or standardized documents:

EN IEC 60529:1991+A1:2000+A2:2013

EN IEC 60079-0:2018

EN IEC 60079-1:2014

EN IEC 60079-31:2014

EN IEC 61000-6-4:2007+A1:2011

Harmonized Standard (RoHS):

DIN EN IEC 63000:2019

Designation:

0102

II 2 G Ex db IIC T6, T5, T4, T3 Gb

II 2 D Ex tb IIIC T85°C, T100°C, T135°C, T200°C Db

PTB 02 ATEX 1116 X

Neustadt, January 28th, 2020

Dipl.-Ing. Martin Hess, Managing Director

15

Further information and service

If  the  information  contained  in  this  instruction  manual
should  not  be  sufficient  in  any  way,  then  INTERTEC
would be glad to be at your disposal to provide further in-
formation and service.

Please  contact  your  INTERTEC  contact  person  or  dir-
ectly contact

INTERTEC-Hess GmbH

Raffineriestr. 8

93333 Neustadt/Donau

Germany

Phone: +49 9445 9532-0

e-mail: [email protected]

Website: www.intertec.info

Warranty

The  legally  defined  warranties  and  warranty  periods  of
24 months are applicable to our scope of supply and ser-
vices.

You  will  find  more  detailed  information  in  the  manufac-
turer warranty from INTERTEC for heating systems and
accessories.

These instructions do not claim to take all

designs, options or changes into consid-

eration, even in association with installa-

tion, operation or maintenance. INTER-

TEC does not accept responsibility for

providing information about changes

made retrospectively.

Summary of Contents for SL MULTITHERM D.A

Page 1: ...Operating Instructions SL MULTITHERM D A HOM499575435Ien 6 03 02 2020 ...

Page 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 7 10 Maintenance 7 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 8 15 Further information and service 8 ...

Page 3: ...on necting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and Eng lish as well as IEC Scheme Certificate IECEX PTB 07 0055X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide in...

Page 4: ...lts 2 T head bolt type 28 15 M 6x15 4 M6 flat square nut 2 Washer shape A 6 4 4 Lock washers shape J 6 4 2 M6 hex nut If one of the components listed here is not included in the scope of delivery then please contact the manufac turer 6 Technical Data Protection class IP66 IP68 1bar 30min Rated voltage max 265 V AC Permitted operating voltage max 275 V AC Rated current in compli ance with VDE 0298 ...

Page 5: ...the per missible bending radius 5 x outer diameter into consid eration In the dust Ex area the applicable requirements of EN 60079 14 must be complied with Illustration 2 Installation example MULTITHERM with TAE or TS and clearance Additional installation material such as rails or panels and also junction boxes are not included in the standard scope of delivery see Installation accessories Page 4 ...

Page 6: ...an IT system an insulation monit oring device needs to be used which switches off the supply as soon as the insulation resistance is no greater than 50 Ω per Volt of the rated voltage refer also to DIN EN 60079 14 section 7 4 ATTENTION Never remove the adapter cable gland Illustration 3 Example heater with KLE connection CAUTION NOTICE Do not remove adapter cable connec tion to connect up the heat...

Page 7: ...ied out by the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of EN 60079 17 and EN 60079 19 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a con tinuity test on the heating circuit Pay attention to th...

Page 8: ...N IEC 60079 1 2014 EN IEC 60079 31 2014 EN IEC 61000 6 4 2007 A1 2011 Harmonized Standard RoHS DIN EN IEC 63000 2019 Designation 0102 II 2 G Ex db IIC T6 T5 T4 T3 Gb II 2 D Ex tb IIIC T85 C T100 C T135 C T200 C Db PTB 02 ATEX 1116 X Neustadt January 28th 2020 Dipl Ing Martin Hess Managing Director 15 Further information and service If the information contained in this instruction manual should not...