www.intertec.info
Operating Instructions SL MULTITHERM D.A
HOM499575435Ien-6
Page 5 / 8
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · [email protected]
NOTICE
Carefully remove
When removing from the packaging and during trans-
port, the connection line must not be stressed or bent.
Free convection may not be impeded. You will find the
minimum distances and installation position in the follow-
ing figure.
The label needs to remain legible.
Please make sure that the absolute heat transfer coeffi-
cient of the surrounding housing is not smaller than 0.5
W/K.
To ensure operational safety, the heater must operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.
The operating temperatures must be adhered to.
The connection cable must be permanently installed up
to the inlet into the on-site junction box, taking the per-
missible bending radius = 5 x outer diameter into consid-
eration.
In the dust Ex area, the applicable requirements of EN
60079-14 must be complied with.
Illustration 2:
Installation example MULTITHERM with TAE or
TS and clearance
Additional installation material, such as rails or panels
and also junction boxes, are not included in the standard
scope of delivery (see
)
and must be ordered additionally.
8
Connection
INFO
The device may only be connected up and secured by a
trained person, taking into account the "rated voltage"
and "rated current" specified on the nameplate.
Where operating voltage = measured voltage (rated
voltage), then the heater is at its rated output. Mains
voltage fluctuations up to 10 % are then permissible.
Each heater with integrated TS thermostat must be pre-
ceded by a 10 A fuse or a motor protection switch with
short-circuit and thermal quick release (set to 10 A) as
short-circuit protection. When using a heater without in-
tegrated thermostat, the fuse protection can be selected
according to the cross-section of the supply cable.