10.3 Extraordinary maintenance
In the event that, following the breakage of a liner, milk goes directly into the tank and pulsator, proceed as
follows:
Suspend milking and replace the damaged sheath.
After replacing the broken liner, wash the Portable iMilk401 with warm water only, disconnecting the
pulsator's filter cartridge and sucking up the warm water from the pulsator twin tube. Alternate
between 5 seconds of water suction and 5 seconds of air. If water starts coming out of the pulsator
hood, suck up air only to prevent water from getting into contact with electrical parts.
Therefore, leave the pulsator operating for approximately 10 minutes to eliminate excess water and
dry the device.
CAUTION
After the device has been washed it is recommended to drain the washing water from the
vacuum pipeline.