8.3 Change parameters
NOTE
In addition to the parameters of all common programs, the parameters only of the actual
program selected will be displayed on entering the menu.
To access the programming mode, first press the
key; a summary will be displayed of the set
parameters.
Simultaneously press the
and
keys to access the list of parameters, with the possibility to change
them. You can scroll through the parameters by means of the
and
buttons. Press
to
access the change mode: set the desired value with the
and
keys.
Then press
to confirm or
not to change the parameter and return to list.
To exit the programming menu, select the EXIT parameter or press the
key.
Disconnect power supply from the panel, disconnecting Combifast to save the changed parameters.
9 CALIBRATION
9.1 1
st
level milk calibration measurement (on each panel)
The
Milk Meter Calib
parameter is used to calibrate measurement of each system Portable iMilk401. Each
stable requires a different setting due to the different vacuum level, tube length, air input and milk
ascent/rising.
Before calibrating, you need to check:
-
That the milk tube installed has an internal diameter of Ø16mm, not less or more
-
That the air inlet holes on the claw are totally unobstructed
-
That the tubes have been properly inserted (refer to
-
That the Portable iMilk401 is properly positioned during milking (refer to
Portable iMilk401 during milking
CAUTION
If the aforesaid checks prove to be incorrect, the Portable iMilk401 does not guarantee the
declared measurement precision.
Summary of
parameters
Program
selected