5640015_07.17_EN
PORTABLE IMILK401
-
Instruction Manual, Operation and
Maintenance original instructions
THIS MANUAL IS THE PROPERTY OF -
InterPuls
S.p.A.
-
ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 38
On completion of milking in which a conductivity alarm was encountered, the summary screen will display
ISC information
7.3.2
Temperature alarm
If the temperature control is activated (
Temper.Control
parameter) and its value exceeds the value set in
Edge Alarm Temp
during milking, the thermometer on the display will start flashing to signal the problem.
NOTE
The temperature alarm indicates that the animal may have problems. A medical examination
is anyhow essential to diagnose any possible disease. The temperature alarm only focuses
attention on possible anomalies encountered during milking and is not a diagnosis
instrument in itself.
7.4 Detachment procedure
The detachment procedure is carried out in the following way:
1. The pulsator stops and the LED located on top of the Portable iMilk401 starts flashing.
2. The shut-off valve is closed and passage to the vacuum is blocked.
3. The
Detachment Delay
counting starts, during which air goes through the claw to decrease the
vacuum level under the teats, facilitating detachment from the clusters. Once the delay has elapsed,
the cylinder removes the clusters.
4. If the suction function has been activated and once
Sweep Delay
has elapsed, the shut-off is re-
opened for a time equivalent to
Sweep Length
to enable suction of any milk left in the claw.
Detachment operations are started at any time during milking by pressing the
key,
After milking, the display indicates a summary of the data
After viewing the summary of last milking, press the
key to go back to stand-by.
Conductivity
alarm indicator
Total amount of
milking from this
panel
Duration of
milking of the
last animal
Conductivity
alarm indicator
Milk production
of the last
animal
Number of the
last animal
milked