8.1 General parameters
Parameter
Description
Default
Values
1 CONTRAST
Enables you to choose the LCD display contrast
5
0 ÷ 10
2 CAN-ID
Only used with the DHM software, it identifies the panel
1
0 ÷ 127
3 Language
Select the software language
(English - Italian – French - Russian)
English
English
French
Italian
Russian
4 DC Power
Not used for the Portable iMilk401 application
DC
DO NOT CHANGE
5 Lock Programs
If it is active, avoid erroneously changing the milking
program. Set to "NO" if you require different set
parameters for various animals, and change the program
used between one animal and another.
Yes
Yes - No
6 Initial phase
Enables you to choose the panel starting phase
Last phase
Last phase
Washing
Milking
7 Unit type
Set to °C/Kg or °F/lb.
°C/Kg
°C/Kg
°F/lb
8 Enable autost
Not used for the Portable iMilk401 application
No
DO NOT CHANGE
9 S-G
Not used for the Portable iMilk401 application
Cows
DO NOT CHANGE
10 Detachment
Not used for the Portable iMilk401 application
Automatic
DO NOT CHANGE
11 Milk meter calib
In order to have a more precise measurement, it enables
you to modify calculation of the quantity milked.
Refer to chapter
12
0 ÷ 30
12 MIn Flow Dripp
Set the minimum milk quantity to move on to the DRIP
phase
0.6
0.01 ÷ 2.00 l/min
13 Min Flow Detach
Set the minimum milk quantity to move on to the
DETACHMENT phase
0.2
0.01 ÷ 2.00 l/min
14 Re Attach Time
After detachment of the clusters and if second milking
starts before this delay elapses, the milked milk will be
added to that of the previous animal.
1
1 ÷ 600 s
15 Temper. Control
Choose when to enable the temperature control.
All
All
Only Wash
No
16 Temper. Calibr
It enables you to calibrate the temperature reading of
the probe. Refer to chapter
10.00
0.00 ÷ 20.00
17 Edge Alarm Temp
If the milk temperature rises above this threshold, the
panel issues an alarm
39.5
35.0 ÷ 45.0°C
18 Conduct Control
Enable conductivity control
Yes
Yes - No
19 Conduct Thresh
It indicates sensitivity in the conductivity reading.
Decrease the said value if there are too many alarms.
40
0 ÷ 60
20 Conduct Delay
Set the initial quantity of milk for which conductivity is
not initially controlled.
3
1 ÷ 20
21 Max Milking Time
Once this time has elapsed, the panel removes the
milking clusters.
15
0 ÷ 180 min
22 Max Wash time
This time starts counting at the beginning of the washing
phase. The panel switches off at the end
120
0 ÷ 250 min