MI - 39
7.4.1
Automatic detachment
Set the
Detachment
parameter to
Automatic
and carry out automatic milking. When the quantity of milk
drops below the set threshold, detachment operations occur automatically and the DVC1000 cylinder
removes the clusters.
7.5 Stimulation
7.5.1
Manual
MANUAL stimulation can be activated from any program (P1
– P3 – P5 – P7 – P9) and at any time during
milking.
By pressing the
key, the pulsator promptly gradually changes the frequency and milking ratio until
reaching the value set in the parameters
Stimulation PR
Stimo Ratio REAR
Stimo Ratio FRONT
After the time set in the
Stimulation Time
parameter, stimulation is stopped and the panel returns to normal
milking conditions
During this phase the display indicates the wording STIM as a milking indicator.
It is possible to activate stimulation many times during the same milking process.
7.5.2
Forced
Stimulation at the beginning of milking is an active phase only in program P9.
Since it is a forced stimulation, you are only required to set P9 as the milking program to activate it.
At the beginning of milking, the panel will always carry out stimulation by following the parameters set for
manual stimulation
Stimulation time
Stimulation PR
Stimo Ratio REAR
Stimo Ratio FRONT
Stimulation
indicator