Section 8, Operating the WaterHeater
Activating the Burner and AC Immersion Element Jointly
•
Turn the burner switch on the Remote Operating Panel to the
ON position. Place the AC circuit breaker to the element ON.
The Burner and AC Heat (green) LED’s on the Remote
Operating Panel will turn ON indicating the diesel burner and
AC immersion element have been selected.
8.4 Activating the Cabin Fan Heaters
through the Thermostats
(Space Heating Module equipped model only) (Burner or AC
Heat on)
•
Any thermostat connected to the Space Heating Module and
calling for heat will cause the cabin fan controlled by that
thermostat to commence running. The ITR cabin fan heater
has a built-in aquastat that prevents the cabin fan from
starting until the coolant in the cabin fan heater itself has
reached a set temperature. Once the room temperature has
reached the temperature called for by the thermostat, the
cabin fan will turn OFF.
8.5 Functions of the Remote Operating
Panel
•
The WaterHeater™ by ITR’s Remote Operating Panel,
Figure 8-2: Remote Operating Panel, contains one ON/OFF
burner switch and three LED’s indicating Burner activation,
AC element activation, and service.
Figure 8-2: Remote Operating Panel
International Thermal Research
8-3