112
Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Chapter 7—Commands
Y – Serial Port Setup
Description
This command is used to establish the communication
parameters of the serial RS-232 port.
Syntax
Yp
1
,p
2
,p
3
,p
4
Parameters
p
1
Baud
rate:
19
19,200
baud.
96
9,600
baud.
48
4,800
baud.
24
2,400
baud.
12
1,200
baud.
p
2
Parity:
O Odd.
(O is uppercase o character; ASCII 79 dec.).
E
Even.
N
None.
p
3
Number of data bits:
7 7 data bits.
8 8 data bits.
p
4
Number of stop bits:
1 1 stop bit.
2 2 stop bits.
Remarks
After receiving this command, the printer will automatically reset
its communication on the serial RS-232 communication port.
There are no such parameters for the USB port.
By default, the printer is set for 9600 baud, no parity, 8 data bits,
1 stop bit.
XON/XOFF handshaking is always used. The printer sends
XOFF when an error occurs. RTS/CTS is not supported
If the current communication setup is not known, it can be
checked by printing a test label (see
Chapter 1
).
Example
Y19,O,7,1
↵
:Sets 19,200 baud, odd parity,
7 data bits, 1 stop bit
Summary of Contents for EasyCoder C4
Page 1: ...Programmer s Reference Manual ESim v4 00 for EasyCoder C4 Bar Code Label Printer...
Page 14: ...8 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 1 General Information...
Page 124: ...118 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 7 Commands...
Page 128: ...122 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 8 Fonts...
Page 151: ......