106
Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Chapter 7—Commands
US – Enable Error Reporting
Description
This command is used to enable the printer’s status reporting
feature with optional direct recovery.
Syntax
US[A][B][E]
Parameters
A
If any error of type A occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
B
If any error of type B occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
E
Error 13 LTS reply control (label taken sensor). Returns error 13 if LTS detects a
label before and after printing.
Remarks
Any or all parameters can be activated at the same time. Refer to
Appendix A for information on error types.
Parameters are saved in the Flash memory.
The format of the error messages is controlled by the
eR
command.
Example
Command
Reply
Comment
USABE
↵
<ACK>
Activate all error fl ags
eRQ,6,R
↵
(no reply)
Setup User-Defi ned Error/Status Character control to
Q for <XOFF> and <R> for <XON>
N
↵
(no reply)
Clear image buffer and errors
AA
↵
(no reply)
Erroneous command type A; Syntax error
P
↵
<NAK>01Q
Print image buffer with error 01
R
Direct recovery error 01 (type A) and continue
Summary of Contents for EasyCoder C4
Page 1: ...Programmer s Reference Manual ESim v4 00 for EasyCoder C4 Bar Code Label Printer...
Page 14: ...8 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 1 General Information...
Page 124: ...118 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 7 Commands...
Page 128: ...122 Intermec EasyCoder ESim v4 00 Programmer s Reference Manual Chapter 8 Fonts...
Page 151: ......