24
Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Chapter 5—Editing in Form Edit Mode
Complete List of the Example
Command
Explanation
↵
CR/LF to start command structure
FK"TEST"
↵
Delete current form named TEST
FS"TEST"
↵
Start store form named TEST
V00,15,N,"Enter Product name:"
↵
Defi ne 1:st variable
V01,10,L,"Enter Model number:"
↵
Defi ne 2:nd variable
V02,8,N,"Checked by:"
↵
Defi ne 3:rd variable
C0,6,L,+1,"Enter Serial Number:"
↵
Defi ne counter
X0,0,4,752,584
↵
Draw a box
LO0,144,752,4
↵
Draw a line
LO440,232,4,160
↵
Draw a line
A40,400,1,1,1,1,N,"Made in Sweden"
↵
Write a 90˚ text line of fi xed data
A24,160,0,5,1,1,R,V00
↵
Write 1:st variable text fi eld
A24,250,0,4,1,1,N,"MODEL: "V01
↵
Write text line, fi xed data + 2:nd variable
A472,312,0,4,1,1,N,"Checked by: "V02
↵
Write text, fi xed data + 3:rd variable
A24,312,0,4,1,1,N,"SERIAL#: "C 0
↵
Write text line, fi xed data + 1:st counter
B280,440,0,1,2,3,96,B,"S"C 0
↵
Write barcode, fi xed data + 1:st counter
GG24,12,"LOGO"
↵
Write graphic from graphics memory
FE
↵
Closing command to store form