Chapter 2: Installation
UltraView IP PTZ 36X Camera User Manual
11
Connections
There are seven built-in alarm inputs to use as internal alarm triggers and two
alarm built-in outputs in the camera housing.
Note
: The DIP switches are not used.
Figure 4: Connections to the UltraView IP PTZ 36X camera circuit board
1. Power supply
C24 VAC power supply and GND.
2. Alarm inputs and outputs
Connect to up to seven alarm input
devices, two alarm output devices and
GND.
3. Video output and audio input/output
VIDEO: Connect a CCTV monitor to the
video terminals.
AIN, AOUT: Connect audio input, audio
output and GND to the audio terminals.
Alarm input and output connections
The alarm output can be used to turn on and off an external alarm device.
Connect a 12 VDC/30 mA external power supply to the alarm output. If using an
AC power supply, an external relay must be used to prevent electric shock and
damage to the device. See Figure 5 below.
Figure 5: External alarm output
Direct current:
Dome camera
relay output