TruPortal IP-based Single Door Controller Quick Reference

Figure 11: IPSDC LEDs and Switches

Callout

Description

State

LEDs

1

D85 Power On

ON: power is present

2

D14 Offline

Normally OFF

3

D15 Address RX

Normally OFF

4

D16 Badge Activity

Normally OFF; flashes when badge is read

5

D17 Database Pending

Flashes while waiting to receive database from host

6

D18 File System Active

Normally OFF

7

D19 Watchdog

Flashes one beat per second if watchdog is healthy

8

D20 Flash Upload

ON when IPSDC is booting up

9

D21 Shutdown Request

Normally OFF/Flashes and then ON

10

D33 Strike Activated

ON during strike activation

11

D24 FACP (not supported by IPSDC)

ON = contact open

12

D25 Door Contact

ON = contact closed; OFF = contact open; Flashing = fault

13

D26 Door REX

ON = contact closed; OFF = contact open; Flashing = fault

14

DS and DS5 Link

ON = link activity; OFF = no activity. Flashing = network activity

15

DS4 and DS8 Collision

ON = Collision

16

DS3 and DS7 Full Duplex

ON = Full duplex; OFF = Half duplex

17

DS2 and DS6 100/10 Mbps

ON = 100 Mbps; OFF = 10 Mbps

Switches

18

SW4 Boot Mode

Manually enables the ICT.

19

SW5 Hardware Reset

Reboots the IPSDC.

20

SW6 Shutdown Request

Initiates Safe Shutdown of the IPSDC. 

21

SW7 Restore Defaults

Returns configuration to factory defaults.

Summary of Contents for TruPortal TP-ADD-1DIP

Page 1: ...TruPortal IPSDC board only Capable of controlling one door No enclosure or readers included Installation Procedure To install the IPSDC perform the procedures described in the following sections in t...

Page 2: ...stom Wiegand Card Format 1 1 Use the System Administration Card Formats page in the TruPortal User Interface to configure Wiegand card formats Set SW1 1 to OFF and set SW1 2 thru SW1 4 to ON SW2 Set a...

Page 3: ...quirements Wattage Calculator worksheet included on the product disc for strike type and size 6 Strike voltage selection Jumper pins 1 and 2 for 24 VDC strikes jumper pins 2 and 3 for 12 VDC strikes 7...

Page 4: ...the cable through ferrite provided as shown in Figure 5 Note Ferrite must be installed inside of the enclosure Figure 3 Using Shielded Cable and Drain Wire Figure 4 Wiring Earth Ground Figure 5 Instal...

Page 5: ...ake sure that the PC is not blocked from connecting to IP address 192 168 6 6 If the workstation normally connects to the Internet via a proxy the proxy settings in the browser may need to be adjusted...

Page 6: ...nclosure tamper W5 4 Strike Voltage Select W2 14 Boot Mode switch SW4 5 Custom Wiegand Card Format DIP switch SW1 15 Hardware Reset switch SW5 6 Reader Out Egress J3 16 Shutdown Request switch SW6 7 D...

Page 7: ...REX 2 17 1K EOL resistors typical 3 Connector J3 18 Reader 2 egress 19 12 VDC Red 20 Ground 0V Black 21 Reader Data 0 Green 22 Reader Data 1 White 23 Door DO green LED Orange 24 26 Not used 27 Drain w...

Page 8: ...uest Normally OFF Flashes and then ON 10 D33 StrikeActivated ON during strike activation 11 D24 FACP not supported by IPSDC ON contact open 12 D25 Door Contact ON contact closed OFF contact open Flash...

Page 9: ...ratings Door DO Reader LED 20 mA 12 VDC maximum Door strike DO relay 2A 28 VDC or 30 VAC maximum Strikes Maximum current 390 mA per strike output See Table 2 on page 2 for recommended strike models a...