TruPortal IP-based Single Door Controller Quick Reference

Figure 9: IPSDC Board Layout

The following table lists the items shown in 

Figure 9

.

Callout

Description

Callout

Description

1

IPSDC board with overlay

11

Network (Ethernet) port J10

2

Reader In (Access) J1

12

Console port J9

3

Door Contact, Request to Exit (RTE) and 
Strike Relay J2

13

Enclosure tamper W5

4

Strike Voltage Select W2

14

Boot Mode switch SW4

5

Custom Wiegand Card Format DIP switch 
SW1

15

Hardware Reset switch SW5

6

Reader Out (Egress) J3

16

Shutdown Request switch SW6

7

DIP Switch 2 (set all to OFF) SW2

17

Restore Defaults switch SW7

8

Status LEDs typical

18

Aux Power Input 24 VDC 

Note:

 Jumpers between pins 3 and 4, and pins 4 

and 5 must remain in place.

9

UCSIMMPlus Module

19

Fire Alarm Control Panel (FACP) Input J6

Note: 

The IPSDC does not support FACP so 

this jumper must remain in place.

10

IPSDC board mounting holes

Summary of Contents for TruPortal TP-ADD-1DIP

Page 1: ...TruPortal IPSDC board only Capable of controlling one door No enclosure or readers included Installation Procedure To install the IPSDC perform the procedures described in the following sections in t...

Page 2: ...stom Wiegand Card Format 1 1 Use the System Administration Card Formats page in the TruPortal User Interface to configure Wiegand card formats Set SW1 1 to OFF and set SW1 2 thru SW1 4 to ON SW2 Set a...

Page 3: ...quirements Wattage Calculator worksheet included on the product disc for strike type and size 6 Strike voltage selection Jumper pins 1 and 2 for 24 VDC strikes jumper pins 2 and 3 for 12 VDC strikes 7...

Page 4: ...the cable through ferrite provided as shown in Figure 5 Note Ferrite must be installed inside of the enclosure Figure 3 Using Shielded Cable and Drain Wire Figure 4 Wiring Earth Ground Figure 5 Instal...

Page 5: ...ake sure that the PC is not blocked from connecting to IP address 192 168 6 6 If the workstation normally connects to the Internet via a proxy the proxy settings in the browser may need to be adjusted...

Page 6: ...nclosure tamper W5 4 Strike Voltage Select W2 14 Boot Mode switch SW4 5 Custom Wiegand Card Format DIP switch SW1 15 Hardware Reset switch SW5 6 Reader Out Egress J3 16 Shutdown Request switch SW6 7 D...

Page 7: ...REX 2 17 1K EOL resistors typical 3 Connector J3 18 Reader 2 egress 19 12 VDC Red 20 Ground 0V Black 21 Reader Data 0 Green 22 Reader Data 1 White 23 Door DO green LED Orange 24 26 Not used 27 Drain w...

Page 8: ...uest Normally OFF Flashes and then ON 10 D33 StrikeActivated ON during strike activation 11 D24 FACP not supported by IPSDC ON contact open 12 D25 Door Contact ON contact closed OFF contact open Flash...

Page 9: ...ratings Door DO Reader LED 20 mA 12 VDC maximum Door strike DO relay 2A 28 VDC or 30 VAC maximum Strikes Maximum current 390 mA per strike output See Table 2 on page 2 for recommended strike models a...

Reviews: