The following chart provides the device numbers that will be reported for trouble conditions.
KEYPAD
PARTITION
1
2
3
4
5
6
7
8
1
192
193
194
195
196
197
198
199
2
200
201
202
203
204
205
206
207
3
208
209
210
211
212
213
214
215
4
216
217
218
219
220
221
222
223
5
224
225
226
227
228
229
230
231
6
232
233
234
235
236
237
238
239
7
240
241
242
243
244
245
246
247
8
248
249
250
251
252
253
254
255
NX1192E MAXIMUM WIRE RUN
(Note: These numbers are for one keypad at the end of the wire. When connecting more
than one keypad to the end of the wire, a heavier gauge wire will be required.)
WHEN CONNECTED TO NX8-E
WHEN CONNECTED TO NX-320
Length in feet
Wire Gauge
Wire Gauge
250'
24
22
500
20
18
1000
18
16
1500
16
14
2500
14
12
SPECIFICATIONS
OPERATING POWER
12 VDC Regulated
Supplied by NX8-E or NX-320
OPERATING TEMPERATURE
32 to 120 degrees F
CURRENT DRAW
110 mA Maximum
75 mA without Sounder
LCD KEYPAD DIMENSIONS
6.4" Wide
5.3" High
1.0" Deep
SHIPPING WEIGHT
2 lbs.
CADDX CONTROLS, INC.
1420 N MAIN STREET; GLADEWATER, TEXAS 75647
TOLL FREE 800-727-2339
FAX 903-845-6811
www.caddx.com
NX1192E INSTALLATION MANUAL
NX1192EIA02
REV. A (04-01-02)