RESET FUNCTION
1) Disarm the system.
2) Enter [
U
]-[7]
The smoke detectors, zone troubles, and zone tampers
have now been reset.
If the keypad begins beeping, the reset did not execute properly. Enter your code to silence
the keypad. Wait a few minutes and repeat step 2 to attempt another reset.
U
U
9 8
Pressing [
U
]-[9]-[8] while the system is disarmed will cause the control to do
a callback for a download. NOTE: A VALID USER CODE MAY BE
REQUIRED AFTER [
U
]-[9]-[8] IF ENABLED IN LOCATION 41 OF THE
CONTROL PANEL. (Refer to the NX-4, -6, -8, -8E Installation Manual)
U
U
9 9
Pressing [
7
]-[9]-[9] while the system is disarmed will cause the control to seize
the phone line for a download. NOTE: A VALID USER CODE MAY BE
REQUIRED AFTER [
U
]-[9]-[9] IF ENABLED IN LOCATION 41 OF THE
CONTROL PANEL. (Refer to the NX-4, -6, -8, -8E Installation Manual)
U
U
CHIME
If enabled in the control panel, entering [
7
]-[CHIME] followed by a user code
will allow a walk-through zone test where all zones become silent and local
(non-reporting). Each time a zone is faulted, the number of the faulted
zone(s) will be displayed on the keypad and the chime will sound. It will also
be entered into alarm memory and the internal log. To exit at any time during
this mode, enter a user code. Otherwise, the
Walk-Test Mode
will
automatically exit after 15 minutes.
PARTITIONED SYSTEMS OPERATION
The NX1192E can be programmed to operate all the system partitions simultaneously. To
set the multi-partition mode, use the
U
U
9 3 function, and answer "YES" to the question
"Master keypad?"
NOTE: [
U
]-[1] followed by a code will temporarily access the Master Mode. The keypad will
revert back to its assigned partition 60 seconds after a keypress or 10 seconds without a
keypress. Press [#] to exit this mode.
LIGHTS IN PARTITIONING MASTER MODE
ARMED will illuminate if ALL partitions are armed.
READY will illuminate if ALL partitions are "Ready". The ready light will flash if all areas
are Ready or Force armable.
FIRE will illuminate if ANY one area has a Fire condition. The fire light will flash if ANY
area has a Fire Trouble condition.
POWER will illuminate if the primary power is connected to the NX8-E control panel.
It will flash if the system has a low standby battery condition.
STAY will illuminate if ANY area has the stay light on.
CHIME will illuminate if ANY partition is in the "Chime" mode.
EXIT will illuminate if ANY area is timing an exit delay. It will flash if ANY area is in the
last 10 seconds of an exit delay.
BYPASS will illuminate if ANY area has a zone bypassed.
CANCEL will flash during an abort delay time. If a code is entered followed by the
[CANCEL] key while this light is flashing, all abortable reports will stop the
communication process to the central station. If a code is entered followed by the
[CANCEL] key during or after an alarm report, the cancel light will illuminate and remain
constant until the central station has received the cancel report.
SOUNDER will sound if ANY area has the sounder on. This includes Entry delay, Exit
delay, Chime, and Alarm.