CHANGING USER CODES

Note: For partitioned systems, someone changing the code of another person must have
access to all or more partitions than the user being changed.

1)  Enter [

U

]-[5]

The LCD Screen will prompt for a code.

2)  Enter [master code]

The LCD Screen will prompt for a user number.

3) Enter the 2-digit (applies to

NX4/6/8) or 3-digit (NX8E) user
number. Remember to use
leading zeros, i.e. "03" or 

003"

for user 3.

The LCD screen will prompt for a new code.

4) Enter the new user code designated for that individual.  The sounder will beep 3 times if it
rejects the code.

5) If another user code needs to be programmed, return to step 3.

6) To exit Code Programming, press [#] while the LCD screen is prompting for a new user
number.

U

U

6

ASSIGNING AUTHORITY LEVEL

Note: You must have authority to the partition you wish to add or remove from another
person’s authority.

1)  Enter [

U

]-[6]

The LCD Screen will prompt for a code.

2)  Enter [master code]

The LCD Screen will prompt for a user number.

3)  Enter the 2-digit (applies to

NX4/6/8) or 3-digit (NX8E) user
number. Remember to use
leading zeros, i.e. "03" or 

003"

for user 3.

The LCD will now prompt you for the first in the following
list of attributes.

PROMPTS

(#1)  Outputs used?

Open / Close Rprt?

Bypass enable?

Arm / Disarm?

If Prompt #1 ("Outputs used?") is
answered NO, the LCD will
display the four messages below.

If Prompt #1 ("Outputs used?") is
answered YES, the LCD will
display the four messages below.

Master code?

Output 4 enable?

Sched arm only?

Output 3 enable?

Arm only?

Output 2 enable?

Reserved

Output 1 enable?

4) Enter a partition number. NOTE: The default allows access to all partitions. The first

keypress will remove access to the partition. To reestablish access, press the partition
number again. 

5) Press [

U

] when completed.

The LCD Screen will prompt you for the next user code.

6) If another user code needs to be programmed, return to Step 3.

7) To exit this feature, press [#].

NOTE TO INSTALLER: Any master arm/disarm code can add or change a user code if
the master code has access to the same partitions as the code being added/changed.
 Consequently, when programming the user codes for a partitioned system, leave at
least one code access to all partitions or you will not be able to add new users
 (can be
"go to program code" if enabled in location 43 of the control panel).   If you desire the
end user to be able to add new codes, you must remove the partition authority from all
blank codes.

Summary of Contents for NX1192E

Page 1: ...MBER AND PARTITION 7 KEYPAD FUNCTIONS 7 7 9 0 READING THE EVENT LOG 7 POSSIBLE LOG MESSAGES 8 7 9 5 SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST 9 7 9 7 SET SYSTEM TIME AND DATE 9 7 0 ADJUST KEYPAD...

Page 2: ...segment is reached press the key This keypress will not save the changes made to current segment but will exit the location To proceed to the next location press the Police key To return to the previo...

Page 3: ...4 4 7 5 50 0 n 6 66 6 8 82 2 0 03 3 C 1 19 9 S 3 35 5 8 5 51 1 o 6 67 7 8 83 3 0 04 4 D 2 20 0 T 3 36 6 9 5 52 2 p 6 68 8 8 84 4 0 05 5 E 2 21 1 U 3 37 7 a 5 53 3 q 6 69 9 8 85 5 0 06 6 F 2 22 2 V 3 3...

Page 4: ...ORATORIO RECIBIDOR TRASERO COCINA EXTERIOR LATERAL SABOTAJE VALLA COMEDOR FACHADA LAVABO SALA VENTANA CONTACTO FUEGO MAGNETICO SALIDA VESTIBULO CRISTAL GARAJE OFICINA SALON ZONA LOADING FACTORY DEFAUL...

Page 5: ...aller level functions These are samples of the displays that will appear in the Function Menu Each time the U key is pressed the next menu item will be displayed Press the number or key to access the...

Page 6: ...custom message you must enable Custom Message Lock under the 7 9 3 function For custom messages in the second language NOTE The above 7 9 2 mode must be exited prior to changing languages 1 Enter 7 4...

Page 7: ...N OPTION Programs special characteristics 1 Display Press 7 For Help 2 Disable LED Extinguish on this keypad 3 On if PIN should be hidden when programming 4 On suppresses beeps when an RF transmission...

Page 8: ...Reports user number date time and partition of closing Exit Err Exit Error Entry Exit zone was faulted at the instant the exit delay expired Rec Close Recent Close An alarm occurred within 5 minutes...

Page 9: ...current hour flashing 3 Use the up and down scroll keys to select the proper hour 4 Enter the 7 key to move to the minutes 5 Repeat steps 3 4 until the entire date is set U U 0 ADJUST KEYPAD TONE 1 P...

Page 10: ...to the prompt to Select Light Number 0 9 4 Repeat steps 2 and 3 until all of the devices have been programmed as desired 5 Press to exit this function U U 4 7 HOUSE CODES FOR X 10 DEVICES When used i...

Page 11: ...The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Close Rprt Bypass enable Arm Disarm If Prompt 1 Outputs used is answered NO the LCD will displ...

Page 12: ...eously To set the multi partition mode use the U U 9 3 function and answer YES to the question Master keypad NOTE U 1 followed by a code will temporarily access the Master Mode The keypad will revert...

Page 13: ...ed Refer to the following table for possible conditions LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE CONDITION Blank Blank Area Not Used or Authorized Dash Dash Area Not Ready Flashing Dash Area Rea...

Page 14: ...l only work if an individual partition is selected SERVICE DISPLAY The following message will be displayed periodically if the security system requires service 6HUYLFH 5HTXLUHG 7 SH IRU KHOS If you se...

Page 15: ...an expansion device has been opened SDQVLRQ 5 DPPHG A radio receiver is being jammed SDQVLRQ 7URXEOH An expansion device or keypad is not reporting to the control panel SDQVLRQ 6LUHQ WURXEOH An expans...

Page 16: ...he end of the wire When connecting more than one keypad to the end of the wire a heavier gauge wire will be required WHEN CONNECTED TO NX8 E WHEN CONNECTED TO NX 320 Length in feet Wire Gauge Wire Gau...

Reviews: