9
Listen In
Listen In - A listen in function has been activated.
Service Start
Service Start - Technician is on site.
Service End
Service End - Technician is off site.
Code Entry
Code Entry - A code has been entered.
First Open
First Open - Reports when the first partition is disarmed.
Last Close
Last Close - Reports when the last partition is armed.
Sprnklr
Sprinkler - Instant sprinkler supervisory report
Clock Set
Clock Set - Clock has been reset.
RF Jammed
RF Jammed - A wireless expansion module is jammed
CleanMe
CleanMe - A smoke detector requires cleaning.
U
U
9 5
SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST
1) Enter [
U
]-[9]-[5]
The LCD screen will prompt for a code.
2) Enter [program code]
The LCD will now display the elapsed time screen.
3) Enter [100's digit] -[10's digit]-[1's digit]-[#]
U
U
9 7
SET SYSTEM TIME AND DATE
1) Enter [
U
]-[9]-[7]
The LCD screen will prompt for a code.
2) Enter [master code]
The date and time will be displayed with the current
hour flashing.
3) Use the up and down scroll keys to select the proper hour.
4) Enter the [
7
] key to move to the minutes.
5) Repeat steps 3 & 4 until the entire date is set.
U
U
0
ADJUST KEYPAD TONE
1) Press [
U
]-[0]
The LCD screen will prompt you to use the scroll keys
located on the right of the display to raise or lower the
tone.
2) Use the up scroll key to raise the
tone. Use the down scroll key to
lower the tone.
The keypad will emit a continuous tone to allow you to
hear the current selection.
3) When the desired tone is reached, press the [#] key to set this tone and exit the mode.
U
Ux
VIEW ZONE STATUS
1) Enter [
U
]-[
N
]
The LCD Screen will display the zone status.
2) Use the up and down scroll keys
to browse through the descriptions.
The LCD Screen will display the list of ALL zones in
sequential order by zone number
3) Press [#] to exit this function.
U
U
3
VIEW ALARM MEMORY
1) Enter [
U
]-[3]
The LCD Screen will display the zone description for
the zones.
2) Use the up and down scroll keys
to browse through the alarm
memory.
The LCD Screen will display the list in sequential order
by zone number.
3) Press [#] to exit this function.