LCD Keypad
22
DISPLAY
DESCRIPTION
Log Full
Log Full
The event log is full. Old events will be pushed
out as new ones enter the log.
Open
Open
Reports user number, date, time and partition of
opening.
Close
Close
Reports user number, date, time and partition of
closing.
Exit Err
Exit Error
Entry/Exit zone was faulted at the instant the
exit delay expired.
Rec Close
Recent Close
An alarm occurred within 5 minutes after the
control was armed.
Autotest
Auto Test
Sending a communicator test at a specified
interval.
Start Prog
Start
Programming
Local programming is started.
End Prog
End
Programming
Local programming is ended.
Start Dnld
Start Download Download session is started.
End Dnld
End Download Download session is ended.
Cancel
Cancel
System is disarmed and the Cancel button was
pressed within 5 minutes of an alarm.
Gnd Flt
Ground Fault
A short to ground has been detected.
Man Test
Manual Test
Bell and/or communicator test while system is in
disarmed condition.
Re-exit
Re-Exit
The exit delay has been re-started without
disarming the system.
Output Trip
Output Trip
A trip has occurred on an expander auxiliary
output.
Data Lost
Data Lost
Communication of a signal has failed (log only
event).
Walk-test
Walk-Test A
zone
“Walk-Test” mode has been activated.
End Test
End Test
Test has been ended.
Cross-Trip
Cross Trip
The first zone of a cross zone has been tripped
(log only).
Expansion
Event
Expansion
Event
An expansion module created an undefined
event.
Partial Arm
Partial Arm
Reports a closing in the stay mode.
Summary of Contents for NX-1248E
Page 1: ......