Programming

The Keypad is programmed via the buttons using a 4 Digit Master code and each User code
has a slot number 001-050 for each 2-8 Digit code to be stored. The Door open time for the
relay can be set for 1-99 seconds or can be set to Toggle On and Off.

To Add a Single User code (2-8 Digits):-

1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes.

2. Enter: 3 digit Slot number 001 to 050 - Double beep.

3. Enter: New Code # Repeat Code - Double beep.

4. Enter: # to exit Programming - Double beep and Red Led goes out.
Note: Individual codes can't be deleted but can be re-programmed into the Slot number.

To unlock the Door:-

Enter: User code # - If correct - Long beep and Yellow Led (If incorrect code - Long beep Red Led)

To Change Door Open time:-

1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.

2. Enter: 251 to change time - Double beep.

3. Enter: Number of Seconds # Repeat Number of Seconds - Double beep.

(Number of seconds must be 01 to 99 or 00 for Toggle option*)

*Note: Toggle option can only be used with 12v DC systems.

4. Enter: # to exit Programming - Double beep and Red Led goes out.

To Delete ALL user codes:-

1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.

2. Enter: 253 to delete all users - Double beep.

3. Enter 8 8 8 8 # 8 8 8 8 - Wait for long beep.

4. Enter: # to exit Programming - Double beep and Red Led goes out.

To Change the 4 digit Master code:-

1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.

2. Enter: 000 to change Master code - Double beep.

3. Enter: New 4 digit Code # Repeat 4 digit Code - Double beep.

4. Enter: # to exit Programming - Double beep and Red Led goes out.

To Reset keypad to Factory defaults:

1. Switch off power to the keypad (check blue Led has gone out).
2. On the back of the keypad (top left corner of PCB) move the black peg from Normal position to
Restore position.
3. Switch on the power and move peg back to Normal position. Unit is new reset to Factory default.

Contents:

Page 2: Installation instructions and Wiring for Fail Locked Electric strike

Page 3. Wiring detail for Fail Un-Locked Electric Strike and Magnetic Lock

Page 4. Programming Instructions and Restore Factory defaults procedure

Specification:

Operating Voltage: 12v AC or DC +/- 10%

Maximum Operating current: 80mA

Maximum Relay Output: 2amps @ 12v DC

Number of users: 1 to 50

Dimensions: 116 x 74 x 22mm