Chapter 4: Web configuration
NS3562-8P-2S User Manual
215
Click the
Add New Rule
button to start setting the PoE schedule function. Click
Apply
after creating a schedule for the selected profile. Then, go to the PoE Port
Configuration page and select
Schedule
from the PoE Mode drop-down menu, and the
profile number from the Schedule drop-down menu, for each port to which you want to
apply the schedule profile.
The page includes the following fields:
Object
Description
Profile
Set the schedule profile mode. Possible profiles are:
Profile1
Profile2
Profile3
Profile4
Week Day
Set the weekday for enabling the PoE function.
Start Hour
Set the hour for enabling the PoE function.
Start Min
Set the minute for enabling the PoE function.
End Hour
Set the hour for disabling the PoE function.
End Min
Set the minute for disabling the PoE function.
Reboot Enable
Enables or disables a PoE port reboot according to the PoE reboot schedule.
Note that if you want the PoE schedule and PoE reboot schedule to work at
the same time, use this function and do not use the Reboot Only function.
This function permits the administrator to reboot the PoE device at the
indicated time as required.
Reboot Only
Permits a reboot of the PoE function according to the PoE reboot schedule.
Note that if the administrator enables this function, the PoE schedule will not
set the time to a profile. This function only applies to PoE port reset at the
indicated time.
Reboot Hour
Sets the hour for PoE reboots. This function is only for the PoE reboot
schedule.
Reboot Min
Sets what the minute for PoE reboots. This function is only for the PoE reboot
schedule.
Buttons
• Click
Add New Rule
to set the PoE schedule function.
• Click
Apply
to apply changes.
• Click
Delete
to delete the entry.
PoE alive check configuration
The IFS PoE managed switch can be configured to monitor connected PD status in
real-time via ping action. Once the PD stops working and does not respond, the PoE
switch restarts PoE port power, and restores the PD to a working state. This increases
reliability and reduces administrator management problems.