![background image](http://html1.mh-extra.com/html/interlogix/cyh-4101/cyh-4101_user-manual_2077134045.webp)
Chapter 1
Programming
35
Power-up action
You can program the UltraView PTZ to perform a certain action when it first powers up. The power-up action
default is home.
To set a power-up action, do the following:
Position reporting
Position reporting provides the capability for a remote device to get pan, tilt, and zoom position information for
doing analysis on the image data. This feature is only supported when the unit is in the Interlogix Impac
RS-485 9600 protocol mode.
To set position reporting, do the following:
1. From
Program select menu 2
, select
System startup
. The
Password protection
screen displays.
2. Using the joystick, navigate right, past the
Password
protection
and
Installation date
screens, to the
Power-up
action
screen (
Figure 73
).
3. Choose the action you want the camera to take when it
first powers up.
•
Select
1
for none, or no actions.
•
Select
2
for home.
•
Select
3
for a specific preset. Press
iris +
to enter the
three-digit-number (000 to 128) of the preset you
want to use.
•
Select
4
for a specific tour. Press
iris +
to enter the
one-digit number (1 to 8) of the tour you want to use.
•
Select
5
for autopan.
Figure 73.Power-up action menu
1. From
Program select menu 2
, select
System startup
. The
Password protection
screen displays.
2. Using the joystick, navigate right, past the
Password
protection
,
Installation date
, and
Power-up action
screens, to the
Position reporting
screen (
Figure 74
).
3. Press
1
to disable, or press
2
to enable.
Figure 74.Position reporting menu
E
CAUTION:
If more than one unit has the positioning reporting feature enabled and the units share the same
control data line, enabling this feature may flood the RS-485 communication lines.