UltraView PTZ
User Manual
18
Synchronization
Set the video signal to be synchronized either to the AC input
frequency (line lock) or to the camera’s internal clock
(
Figure 36
).
Select option
1
to select line lock. If you want to enable this
feature, press the
set
button. Press
iris+
to engage line lock. You
may need to wait several seconds for synchronization to be
completed and to return to the confirmation menu.
Note:
If after pressing the
set
button, your menus disappear, press the
iris -
button to escape out of this setting. The setting will go back
to option 2.
Figure 36.Synchronization menu
Select option
2
to set the video signal to the camera’s internal
crystal (default).
Adjusting the vertical phase (
Figure 37
) requires an oscilloscope
or a KTS-56 phase adjustment tool.
Figure 37.Vertical phase adjust
Temperature display
Show the temperature on the screen (
Figure 38
).
•
Select option
1
to disable temperature display (Default).
•
Select option
2
to enable temperature display, showing
Fahrenheit.
•
Select option
3
to enable temperature display, showing
Celsius.
Figure 38.Temperature display
To set the display area (
Figure 39
), do the following:
1. Navigate to the fourth option,
Display row
.
2. Press the
iris+
key.
3. Use the joystick to navigate to a number between 01 and
011 (NTSC) or 014 (PAL).
4. Press the
iris
+
to set the row.
Figure 39.Setting display area