2.2.2.n.4.9.4 Total pic cnt
Total pic cnt:
12
The Total picture counter shows how many pictures were stored on the PIR
camera expander flash memory since the beginning of its lifetime.
2.2.2.n.4.11 Delete pics
11 Delete pics
>Cancel<
Choose OK and press Enter to remove all stored pictures from the wireless PIR
camera expander.
Four-door expander specific options
2.2.2.n.4.6 Output modules
6 Outp. modules
>0<
Enter the number of output controllers fitted to the door controller.
Allowed range is 0 to 32. 0 means no clocked output card connected. Note that
there are four open collector outputs available on the door controller for a 4-way
relay card.
2.2.2.n.4.7 Region count limit
7 Reg cnt limit
>65534<
When the number of users reaches this limit, the door controller sets an internal
flag (region count limit) that can be used in the door controller macro logic. You
may activate events when a certain number of users are in a region.
The allowed range is 0 to 65534.
Examples:
• Activate a sign when a car park is full.
• Set areas when the last person has left the region, or unset areas when the
first person enters the region.
2.2.2.n.4.8 Macro Logic
00>Add macro
01 Macro 1
Use the menu to program door controller macros.
For more information on macros, see “Door controller macro logic” on page 70.
Summary of Contents for ATS1500A-IP-LP
Page 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...