Chapter 4: Programming
108
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
How to program the options
Accessing the installer programming menu
The Advisor Advanced system is programmed from the installer programming
menu. Before accessing the programming menu, the system administrator must
unset the system. Depending on the system settings, you also can be prompted
to open the panel housing prior to configuring the system.
How to access the installer programming menu
1. Start with this LCD display:
UTC F&S
TUE 27 May 10:00
2. If the option “8.2.1 User code required” (see page 237) is set to Yes, the
engineer access must be granted by the manager first. The manager must log
in, activate the “Service In” option, and logout. Now the installer can login
within the time period defined in “8.1.3.6 Installer in-time” on page 235.
3. Press Menu. The display shows:
Enter card/code
>_
4. Enter your PIN and then press Enter
.
Alternatively and if configured you may also present a card to the reader.
The following display appears:
Inh reports
>Yes<
5. Select Yes if you want to inhibit all reports during system programming.
Reports include reporting to central station as well as reporting events in the
logs.
6. Press Enter. The next screen shows whether tampers are inhibited and areas
are unset:
Inh tampers
Unset areas
7. Press Enter again. You are now in the programming menu. The following
display appears:
1>Service menu
2 Device menu
Summary of Contents for ATS1500A-IP-LP
Page 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...