Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
327
Appendix B
Advisor Advanced
reporting codes
Table 33 below shows descriptions of SIA, CID, and VdS reporting codes used in
Advisor Advanced.
Table 34 on page 332 lists allowed values for the appropriate reporting codes.
Table 33: SIA, CID, and VdS reporting code descriptions
#
SIA
code
VdS
code
CID
code
Function
Note
Reporting
priority
1.
AN
0xB0 R393 Detector dirty restore
Low
2.
AR
0xB2 R301 AC restore
Low
3.
AS
0x30 E393 Detector dirty
Low
4.
AT
0x32 E301 AC trouble
Medium
5.
BA
0x22 E130 Burglary alarm
Alarm / input in mask /
trouble when set
Medium
6.
BB
0x51 E570 Burglary bypass
Alarm inhibit
Low
7.
BC
0x52 E406 Burglary cancel
Cancel alarm by user / key /
remotely
Low
8.
BJ
0xB0 R381 Detector supervision
restore
Low
9.
BR
0xA2 R130 Burglary restore
Low
10. BT
0x30 E380 Burglary trouble
Input in mask / trouble when
unset
Low
11. BU
0xD1 R570 Burglary unbypass
Alarm uninhibit
Low
12. BV
0x00 E139 Alarm confirm
ACPO
Medium
13. BW 0x80 R139 Restore confirmed
alarm
ACPO
Low
14. BZ
0x30 E381 Detector supervision
Low
15. CF
0x51 E408 Forced closing
Set by user / by key
Low
16. CG 0x62 E456 Part set
Part set by user / by key /
remotely
Low
Summary of Contents for ATS1500A-IP-LP
Page 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...