Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
125
1.2.2 ShockSens test
1>Panel
2 Input exp
Using the ShockSens test menu, you can test shock sensor sensitivity.
Select the input location first (panel, internal or external expander). Then enter
the (physical) input number on this location.
The input state is displayed.
Panel 1.1
normal 0
Apply shocks to the structure. The menu shows the input state and the shock
gross level (see “4.1.n.7.2 Gross level” on page 183 for more information).
The correct setting for gross attacks can be set to the value + 1 as an alarm
should only be activated when exceeding the test attack.
1.2.3 Outs&triggers
1>Output test
2 Trigger state
The Outputs and Triggers menu allows you to test outputs and check trigger
states.
1.2.3.1 Output test
1>Outputs
2 Keypad LEDs
The Output test allows you to check outputs and LEDs.
1.2.3.1.1 Outputs
Use the Outputs menu to test system outputs.
Select the output location first (panel, internal or external expander, or keypad).
Then enter the output number on this location.
The current output state is displayed.
Panel 1.1
Off
You can now:
• Toggle its state using the Enter button.
• Scroll through the list of outputs. Press Up or Down.
• Exit output test. On exit, the output returns to its original state. Press Clear.
1.2.3.1.2 Keypad LEDs
1>Keypad 1
2 Keypad 2
Use the Keypad LEDs menu to test keypad and reader LEDs.
Summary of Contents for ATS1500A-IP-LP
Page 300: ...Chapter 6 Software 294 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 306: ...Chapter 7 Troubleshooting 300 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 316: ...Chapter 8 Regulations 310 Advisor Advanced ATSx500A IP Installation and Programming Manual...
Page 348: ...Glossary 342 Advisor Advanced ATSx500A IP Installation and Programming Manual...