Alliance AL-4017/AL-4617 Control Panel

Installation Manual

Summary of Contents for Alliance AL-4017

Page 1: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual ...

Page 2: ...E TERMS AND CONDITIONS DO NOT INSTALL OR USE THE SOFTWARE OR IF ALREADY INSTALLED IMMEDIATELY CEASE ALL USE OF THE SOFTWARE AND PROMPTLY UNINSTALL ALL COMPONENTS OF THE SOFTWARE 1 License In this Agreement you the purchaser of the rights granted by this Agreement are referred to as You or Your whether an individual or a business entity of any kind Subject to the terms and conditions of this Agreem...

Page 3: ...Software in the sole discretion of UTC FIRE SECURITY To obtain a repair or replacement of nonconforming Software contact UTC FIRE SECURITY Customer Service toll free at 888 432 7327 or online at ZZZ XWFILUHDQGVHFXULW FRP during the Software Warranty Period Your exclusive remedy under this limited warranty for defective media is replacement of the defective media To receive replacement media under ...

Page 4: ...so are restricted as provided by paragraphs b 2 and b 3 of the Rights in Noncommercial Technical Data and Computer Software Small Business Innovative Research SBIR Program clause at DFARS 252 227 7018 YOU ACKNOWLEDGE THAT YOU HAVE READ AND UNDERSTAND THIS AGREEMENT AND AGREE TO BE BOUND BY ITS TERMS YOU FURTHER AGREE THAT THIS AGREEMENT IS THE COMPLETE AND EXCLUSIVE STATEMENT OF THE AGREEMENT BETW...

Page 5: ...oduct identifier that has the format US AAAEQ T XXXX the digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical t...

Page 6: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual vi ...

Page 7: ...outing 7 Auxiliary power supply connections 8 Nonpower power limited wiring 9 Control panel connections 10 Zone input connections 11 PSTN connections 12 Installer programming menu 13 Battery capacity 14 Battery calculation worksheet 16 Formulas 17 Absolute maximum loads 18 Specifications 19 General specifications 19 AL 4017 external terminals 19 AL 4617 external terminals 20 UL compliance statemen...

Page 8: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual viii ...

Page 9: ...ublication library on page 22 for instructions on accessing our online publication library Note A qualified service person complying with all applicable codes should perform all required hardware installation Conventions used in this document The following conventions are used in this document Safety terms and symbols These terms may appear in this manual Bold Menu items and buttons Italic Emphasi...

Page 10: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual x ...

Page 11: ...wing control panel board two position and three position terminal blocks that can be combined to provide a variety of terminal block configurations clip in and screw in male female standoffs battery wires and mounting screws Inspect the package and contents for visible damage If any components are damaged or missing do not use the unit contact the supplier immediately If you need to return the uni...

Page 12: ...with UL 365 UL 690 and UL 1610 you must install the main control panel within a safe vault or Extent 1 stockroom All Alliance system enclosures contain four mounting holes located in the corners of the enclosure Use appropriate mounting hardware to mount the enclosure to the mounting surface and the batteries to the enclosure as shown in Figure 1 For the AL 4017 24 VAC transformer use the 1690 tra...

Page 13: ... 32 x 1 4 in screws provided with the transformer Figure 1 on page 2 4 It is important that you provide the proper grounding to the enclosure Use two male female standoffs to secure both the earth ground and enclosure ground wires Figure 1 on page 2 When securing the ground wires use the internal tooth star washers provided with the enclosure between the standoff and the wire connector All connect...

Page 14: ...e board Figure 4 in the enclosure Figure 2 on page 3 To ensure proper grounding tighten screws securely Figure 4 Control panel board 8 To comply with FCC Part 15 B you must install ferrites on each of the AC wires For mounting details refer to the instructions provided with the ferrites PSTN connection E Prom Flash Ram Kill TX RX J18 J20 L1 TST1 TST2 J7 J8 Zone inputs Power inputs auxiliary power ...

Page 15: ...ing to polling TX Comms Red LED flashes when the panel is polling remote units It must always be active RX1 Modem Yellow LED flashes when data is being received from a device connected to the PSTN dialer line J15 J16 or J18 serial port RS232 communication to PC TX1 Modem Red LED flashes when data is being sent from the panel to a device connected to the PSTN dialer line J15 J16 or J18 serial port ...

Page 16: ... connections to the enclosure beware of paint The earth connection of every piece of equipment in the system can be used for connecting the shielding of shielded cables If a device such as a keypad is placed in a plastic enclosure the earth lug of the device does not have to be connected Panels in a single building If several enclosures or devices are connected to earth ground in one building the ...

Page 17: ... of the local power supply to the on the arming station and connect the 0 V from the power supply and 0 V from the system bus to the arming station terminal Figure 5 The first and last devices on the system bus must be terminated All other devices on the system bus must not be terminated Figure 5 System bus connection Shielded cable routing Connect the shielding of all shielded cables used in the ...

Page 18: ... panel or an AC powered DGP with auxiliary outputs you must use a UL listed power supply suitable for burglar alarm applications such as the Altonix AL300ULX Figure 7 Tie all 0V terminals together Do not connect the 12 terminals together Figure 7 Auxiliary power supply connections D D 0V D D 0V 12 D D 0V 12 DGP RAS Control panel Altronix AL300ULX auxiliary power supply _ ...

Page 19: ...y 1 4 in minimum from power limited wiring Figure 8 Disconnect the AC power via a dedicated circuit breaker before servicing Figure 8 Power and nonpower wiring Nonpower limited wiring Power limited wiring Nonpower limited wiring PSTN connection Power limited wiring ...

Page 20: ...ust install a 1k resistor across the external siren outputs The first and last device on the system bus Comms must be terminated Figure 9 Controller wiring connections AC do not short circuit Battery Auxiliary power _ _ _ _ SW SW S S S S _ 12 0V D D T C External siren output Internal siren output 8 ohm 15 watt Strobe output MPI 35 or EQ Comms system bus Tamper input Bell relay output AL 4017 NEG C...

Page 21: ...te Dual zone is not acceptable for UL 365 UL 609 and UL 1610 compliance Figure 11 Single and dual zone alarm input wiring 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C 10 C 11 C 12 C 13 C 14 C 15 C 16 C Zone inputs Single zone Dual zone Alarm input Alarm input C C 4 7 K 4 7 K 4 7 K NC NC NO NC closed alarm open alarm or open tamper or NO closed tamper trouble trouble open alarm ...

Page 22: ...N line Figure 12 PSTN connections PSTN connection Tip green Ring red RJ31X Premises tip Premises ring RJ45 RJ11 Premises phone RJ45 Control panel Chassis ground BX AX B A J8 J7 AC BATT COMMS Zone inputs A to pin 5 on RJ45 cable B to pin 4 on RJ45 cable AX to pin 1 on RJ45 cable BX to pin 8 on RJ45 cable PSTN connection Tip green Ring red RJ31X Premises tip Premises ring RJ45 RJ11 12 Premises phone...

Page 23: ...s 36 Reserved menu 10 Program text 37 Reserved menu 11 Version number 38 Reserved menu 12 LED test 39 Reserved menu 13 Time zones 40 Reserved menu 14 Reset to default 41 Reserved menu 15 Alarm group restrictions 42 Reporting class database 16 Event to outputs 43 Test calls 17 Auto arm disarm 44 Reserved menu 18 Areas assign to vault 45 Reserved menu 19 Area linking 46 Reserved menu 20 System codes...

Page 24: ... standby current column For the control panel worksheet this value is 200mA b In rows for any expansion modules enter the operating current for the module in the Standby current column Multiply the value in the Standby current column by the attached quantity of modules of that type Enter the result in the same row in the Total standby current column If any row contains AL 1191 or AL 1193 card read...

Page 25: ...t for your system Formula 5 Due to natural aging effects on batteries over time temperature cycles and varying levels of discharge a derating factor is applied to compensate for these variables Consult the battery manufacturer data sheets for the appropriate derating factor Formula 5 shows how to apply a typical derating factor of 1 15 to the minimum battery capacity requirement to determine the a...

Page 26: ...xt siren 1000 mA Int siren 1000 mA Strobe 1000 mA AL 4617 200 mA Aux power 3000 mA Ext siren 1000 mA Int siren 1000 mA Strobe 1000 mA Comms bus 1000 mA AL 11XX 120 mA AL 1170 45 mA AL 1191 25 mA 80 mA AL 1193 25 mA 80 mA AL 1205 75 mA Aux power 250 mA Siren 1000 mA AL 1206 25 mA AL 1210 53 mA AL 1220 53 mA AL 1255 275 mA Aux power 1000 mA Siren 1000 mA AL 1256 1265 275 mA Aux power 3000 mA Siren 1...

Page 27: ... Conversion factor x Required minutes in alarm x Conversion factor mA x 001Amp mA x minutes x 0167 hours min Ah alarm Amp hours 3 Total active current x Conversion factor x Required seconds active x Conversion factor mA x 001Amp mA x seconds x 000278 hours sec Ah active Amp hours 4 Standby Amp hours Alarm Amp hours Active Amp hours Minimum battery power required Ah 5 Minimum battery power required...

Page 28: ...u have chosen you must install appropriate batteries or adjust the system configuration to meet the battery power requirements AL 4017 AL 4617 Table 5 Absolute maximum loads for the AL 4017 Required batteries Maximum continuous load for 24 72 hr standby with 15 min alarm and 1 active card read 5 min 24 hour 72 hour Two 17 2 Ah Maximum total 750 mA Maximum aux 500 mA Maximum total 325 mA Maximum au...

Page 29: ...ncondensing Listings UL 294 Standard for Access Control System Units UL 365 Standard for Police Station Connected Burglar Alarm Units and Systems UL 609 Standard for Local Burglar Alarm Units and Systems UL 1610 Standard for Central Station Burglar Alarm Units UL 1635 Standard for Digital Alarm Communicator System Units Part Terminal Description Min Typ Max Unit J17 AC Input 16 5 1 24 2 2 1 VAC A ...

Page 30: ...Unit J17 AC Input 18 VAC BATT Battery connection Battery charge Battery AH rating 9 17 2 12 14 1 34 4 VDC A AH J14 AUX POWER Auxiliary power outputs 9 13 8 14 3 1 VDC A J10 COMMS System bus power output 9 13 8 14 1 1 VDC A J13 EXT Siren INT SIREN STROBE SWT Alarm outputs 9 9 9 9 13 8 13 8 13 8 13 9 14 14 14 14 VDC VDC VDC VDC J9 BELL Dry relay output 30 1 VDC A ...

Page 31: ... minutes refer to the Alliance System Programming Manual 14 System tamper activates siren and strobe must be set to YES refer to the Alliance System Programming Manual 15 Latching system alarms must be set to YES refer to the Alliance System Programming Manual 16 Siren types must be set to l refer to the Alliance System Programming Manual 17 Enable PSTN line monitor must be set to YES refer to the...

Page 32: ...y available to all of our customers on our website To access our publication library go to our website at the following location http www XWFILUHDQGsecurity com In the Tools area at the top click the Publication Library link After you register and log on you may search through our online library for the documentation you need 1 Table 7 Sales and support contact information Sales Technical support ...