load.UP manual, page 4 

©

 

InterCard GmbH Kartensysteme

 

Main parameters screen

 

 

 

 

 
 
 

 
 

 
 

 
 
 

 
 

To enter the Parameters menu touch each of 
the four corners of the screen once in any 
order but not all at once; a keyboard will then 

pop up; enter the Menu Password which by 
default is 12345. It is highly recommended you 

change the default password as soon as you 
install the load.UP. From here you have access 

to everything shown in the picture above. 
 

Network settings 

 

 

Remember to make a note of all settings 
deployed and keep them in a safe location. 

 

Static IP/DHCP: 

Select Static IP to manually manage 

your IP pool.  Select DHCP to obtain the subnet mask, 
gateway IP and client IP automatically. Note: Not all 
server applications will work with DHCP since they 

operate off a fixed IP and can’t have it changing when 
the DHCP lease expires so check with your software 

provider before making this decision.   
 

Print Server:

 

IP of the print server or the server 

running the application communicating with the 
load.UP 

 

Client IP:

 

client IP assigned to this load.UP. Read 

only in DHCP mode. 

 

Subnet Mask:

 subnet on which the load.UP is to 

operate. Read only in DHCP mode.   

 

Gateway IP:

 

IP of local network’s Gateway. Read 

only in DHCP mode. 
 
You must reboot the load.UP for changes to take 

effect.  

 

System Screen 

 

 

 

Here you can activate four 

cumulative 

logging levels.

  You should leave this off 

unless requested to turn it on by InterCard 
support because it does adversely affect 

performance especially in Debug mode.  

Info

Mainly used to represent current 

progress of the application. It shows the boot 

up process, software versions, IP data and a 
few other basic items.  

+ Warning

Useful when the application has 

potentially harmful situations such as USB port 

not opening, printer not communicating, error 
codes from the co-processor, etc. 

+ Error

Indicates an error in application but 

app will keep running. Currently this is used to 
log serious communications errors. 

+ Debug

Useful information for developers to 

debug the application. This is very data hungry 
so should not be turned on unless told to by 

InterCard support.  
 

Retrieving the log file is only possible via a 
console application or Win SCP. 
 

Menu Password

 

sets the password used to 

access the Parameter’s menu and can be up to 

8 numeric digits long. The default password is 
12345 which should be changed as soon as the 

load.UP is installed. If you forget your own 
password contact InterCard support for help.

 

 

Summary of Contents for load.UP

Page 1: ...InterCard Villingen Schwenningen Germany load UP Account loader Product Guide...

Page 2: ...parameters screen Network settings System settings Page 5 Locale setting Card readers Card testing Page 6 Display menu Welcome screen Meters About screen Page 7 Paper replacement Internal components W...

Page 3: ...al order Coin acceptor changer Your load UP may be ordered with an electronic coin mechanism capable of validating up to six coin values Bank card terminal For secure payment by debit credit card fees...

Page 4: ...te Read only in DHCP mode Gateway IP IP of local network s Gateway Read only in DHCP mode You must reboot the load UP for changes to take effect System Screen Here you can activate four cumulative log...

Page 5: ...ge return It s important to note that the load UP does not alter in any way the data read from USB card readers So when setting up programmable readers it s important the output string look like the a...

Page 6: ...ad of the standard InterCard welcome screen If you d like to make your own welcome screen use the settings below and use the web interface to load the screen into the load UP Dimensions 640 x 480 File...

Page 7: ...ler and close the black paper lid the printer should detect the paper and auto feed If not press the LF button on the side of the printer to pull it through Internal Components 1 Touch Screen Display...

Page 8: ...is plugged into to 110V or 220V and is powered up 2 Verify that you have a network link by checking the green link LED located a couple of mm from where the network cable plugs into the board You can...

Page 9: ...ifferent and also require different firmware Dispenser Printer 24V Network port 1 Network port 2 Open collector LED drivers General purpose inputs MDB Coprocessor reset Connection to main board Design...

Reviews: