33
Activate an alarm
Turn system-controlled lights on and off. (See also "Controlling Lights (LIGHTS)" on
page 30.)
Bypass sensors indirectly. (See also “Bypassing Normally Armed Sensors
■
To arm the system from a Keychain Touchpad:
1.
Close all perimeter doors and windows.
2.
Check to see that the panel’s READY light is on or blinking.
or– If the READY light is not on or blinking, press the
STATUS
button at the panel or a
touchpad to learn if there are any system problems.
The system’s voice message should provide you with the number of any sensors that
are open. After double-checking those sensors, if the READY light is still not on or
blinking, refer to "Bypassing Normally Armed Sensors (BYPASS)" on page 28. You
also should contact your security consultant to resolve the problem.
3.
Press the Arm button until the light blinks.
The panel’s STAY or AWAY light turns on, and the panel and interior sirens sound
two or three beeps at the beginning of the exit delay.
NOTE:
Depending on programming, a Keychain Touchpad may arm
your system to the next higher arming level or directly to level 3 NO
DELAY.
4.
Exit the premises within the delay time, if you are leaving.
When the delay time expires, the panel and interior sirens sound two or three more
beeps. If you are still on the premises and want to leave, disarm and rearm the system
to prevent an accidental alarm.
■
To arm the system with no alarm delay from a Keychain
Touchpad:
1.
Close all perimeter doors and windows.
2.
Check to see that the READY light is on or blinking at the Panel.
3.
Press the Arm button, then press the Star button and hold until the light blinks.
The Panel’s STAY or AWAY light turns on, and the Panel and interior sirens sound
arming level beeps. The NO DELAY light turns on, and the Panel and interior sirens
sound arming level beeps again.
NOTE:
Disarm the system before opening a perimeter door or window, or
an accidental alarm may occur.
NOTE:
Depending on programming, a Keychain Touchpad may arm
your system to the next higher arming level, or directly to level 3
NO DELAY.
Technical Manuals Online! - http://www.tech-man.com
Summary of Contents for Commander 2000
Page 10: ...10 Technical Manuals Online http www tech man com ...
Page 26: ...26 Technical Manuals Online http www tech man com ...
Page 38: ...38 Technical Manuals Online http www tech man com ...
Page 48: ...48 Technical Manuals Online http www tech man com ...
Page 52: ...52 Technical Manuals Online http www tech man com ...
Page 54: ...54 Technical Manuals Online http www tech man com ...