17
Entering and Exiting Premises
While the system is armed, delay times let you enter or exit through designated delay
doors without causing an alarm. A delay door is any door that is assigned a delay time. If
you activate any sensor before you open the delay door, an instant alarm sounds. When
entering the armed premises, you must disarm the system within the entry delay time.
After arming the system, you must exit the premises before the exit delay time expires.
There are two types of delays: standard and extended. Your security consultant will set up
and explain your system’s delays. Contact your security consultant to have your delay
times changed.
Entering the Premises
To prevent an alarm when entering the armed premises, you must:
■
Enter the extended delay door and disarm the system within the extended
delay time.
or– Enter the standard delay door and disarm the system within the standard
entry delay time.
or– Enter the extended delay door, then enter the standard delay door and disarm
the system within the standard entry delay time or within the time remaining
for the extended delay, whichever is less.
Example: The extended delay is set to 4 minutes, and the standard entry delay is
set to 32 seconds. If you enter the extended delay door and then open the standard
delay door after 3 minutes and 50 seconds, you have 10 seconds to disarm the
system.
If you enter the extended delay door and open the standard delay door after 2
minutes, the extended delay is canceled and you have 32 seconds to disarm the
system.
Exiting the Premises
To prevent an alarm when exiting the armed premises, you must:
■
Exit the standard delay door within the standard exit delay time.
or– Exit the extended delay door within the standard exit delay and the remain-
ing extended delay.
Example: The standard exit delay is set to 32 seconds, and the extended delay is
set to 4 minutes. If you arm your system and exit the standard delay door in 22
seconds, then you must exit the extended delay door within 4 minutes and 10 sec-
onds.
Technical Manuals Online! - http://www.tech-man.com
Summary of Contents for Commander 2000
Page 10: ...10 Technical Manuals Online http www tech man com ...
Page 26: ...26 Technical Manuals Online http www tech man com ...
Page 38: ...38 Technical Manuals Online http www tech man com ...
Page 48: ...48 Technical Manuals Online http www tech man com ...
Page 52: ...52 Technical Manuals Online http www tech man com ...
Page 54: ...54 Technical Manuals Online http www tech man com ...