MEQ-2000
24/96 Multimode Equalizer
MEQ-2000 Parameter Identifier for DEBUG
Debug-Character
Byte Data
Description
0
01h
ID Character for Monitor
1
cc MSB
Character MSB
2
Cc LSB
Character LSB
MEQ-2000 Parameter Identifier for RTA and Meter Change
The value of a frequency beam is sent only if it has changed. For transfer of beam values,
Polyphonic Aftertouch sysex message is employed as follows:
RTA Change
Byte Data
Description
0
0xA0
Polyphonic Aftertouch used for RTA (Running Status supported)
1
2
bb
0 - 30 = RTA Band 0 to 30
100 -105 = Meter (In, Out, Gain reduction for Limiter and Com/Lim)
3
ll
RTA Level 0x00 to 0x7F
MEQ-2000 Parameter Identifier for MUTE and BYPASS
For MUTE and BYPASS functions, the Control Change message is employed as follows:
MUTE/BYPASS
Byte Data
Description
0
0xB0
Control Change message for MUTE and BYPASS
1
nn
Controller number, Bypass = 0x0F, Mute = 0x68
2
vv
Controller value, 0x00 = OFF, 0x7F = ON