MEQ-2000
24/96 Multimode Equalizer
RTA MODE Screen
Pressing the
MODE
key accesses the
RTA MODE
screen, which allows for global setups for
the
RTA
module.
In this screen, parameters are selected with the
and
cursor keys and adjusted
with the parameter wheel. After every change,
ENTER
appears at the
F5
key, and must
be pressed to confirm the change. Default settings can be selected with the
F1
(
DEF
)
key. Pressing the
F6
(
EXIT
) key returns to the
RTA
screen.
If the MEQ-2000 is in measurement mode (
ME-1
or
ME-2
),
GREF
(
GEQ
Reference) appears
over the
F3
soft key. Pressing this key stores the current spectral envelope as a weighting
reference for the
GEQ
module in
RE-1
,
RE-2
,
MA-1
and
MA-2
modes.
Global parameters available in the
RTA MODE
screen are:
BEAMS
switches the spectral display beams ON or OFF. OFF displays only the
spectral envelope.
DECAY
adjusts the fall-back time for the beams display, over a range of 500 to
5000ms, in 10 ms steps.
RMS-IT
selects the integration time for RMS level measurement, over a range of
10ms to 20min in 16 increments. Typical RTA function utilizes a 50ms
integration time; use very long integration times for room characteristic
measurements.
SOURCE
selects the spectrum analyzer’s source, between the input or output
stages. It allows for a comparison of the signal spectrum before and after
processing.
In measurement modes (
ME-x
), the spectrum analyzer input is
permanently connected to the input (
ME-1
) or the output (
ME-2
),
therefore a dashed line - - - appears in this field.
PEAKHOLD
activates the peak hold function.
P-HOLD
adjusts the hold time, over a range of 50 to 5000ms in 10ms steps. An
INFINITY
setting, which holds peaks indefinitely, is also available.
P-DECAY
adjusts the decay time, over a range of 50 to 5000ms in 10ms steps.
Default values are
ON, 1s, 50ms, INPUT ( - - - ), ON, 2000ms, 2000ms.
32
Summary of Contents for MEQ-2000
Page 1: ...MEQ 2000 24 96 Multimode Equalizer Copyright 2004 Inter M Corporation...
Page 4: ...MEQ 2000 24 96 Multimode Equalizer 4...
Page 12: ...MEQ 2000 24 96 Multimode Equalizer OVERVIEW Signal Flow Diagram 12...
Page 42: ...MEQ 2000 24 96 Multimode Equalizer Typical Digital Interconnections 42...
Page 49: ...MEQ 2000 24 96 Multimode Equalizer UTILITY MENU STRUCTURE 49...
Page 56: ...MEQ 2000 24 96 Multimode Equalizer Block Diagram 56...