MEQ-2000
24/96 Multimode Equalizer
Global parameters available in the
GEN MODE
screen are primarily related to the sweep
function:
CH LINK
determines the channel coupling status:
OFF
selects dual channel mode, with two independent channels.
CH1
→
2
couples the channels with
CH1
slaved to
CH2
.
CH2
→
1
couples the channels with
CH2
slaved to
CH1
.
SWEEP TYPE
selects the type of sweep: ONE-TIME switches the generator off after a
single pass; CONT provides continuous sweeping as long as the generator
is on.
SWEEP DIR
selects from an upward sweep, downward sweep, or alternating up-down
sweep.
INTERVAL
sets the duration of a single sweep step:
100ms, 300ms, 500ms, 1s, 3s, 5s,
10s, 30s
,
INF
. In the
INF
mode, pressing the ON button twice moves to the
next step.
Default values are
CH1
→
2, CONT, UP, 1s.