I N S T A L L A T I O N M A N U A L
C I T Y 2 S L I D E ™
11
Rev. 7/15 (SBK-CITY2 INSTL)
Fig. 1
Minimum Concrete Pads – CITY 2™ Slide
(Plan View – NOT to Scale)
Pool Edge
5 concrete pads are needed:
(1) 12” wide x 32” long x 12” deep
(4) 16” wide x 16” long x 12” deep
Center feet on pads
When installing an Inter-Fab City 2™ slide using a paver kit, you must ensure that all standard
installation requirements are met. The slide must be compatible with the type of pool on the intended
installation and all ANSI/APSP/ICC-5 2011 requirements must be met. Refer to installation manual.
Figure 1 illustrates an example of the minimum concrete pads recommended for the City 2™ slide.
Specific slide position and concrete pad orientations may vary. Make sure to allow for water stub
up location near the ladder section of the City 2™ slide when pouring the concrete pad for the ladder
section. In order to ensure proper placement, you will need to set the slide up first to determine
where the concrete pillars will be located.
Figure 2 shows a side view illustration of the City 2™ slide foot deck anchor and wedge anchors
used in a paver installation. NOTE: 4 ea. CITY-DECK ANCHOR are also required (not included
with slide or paver kit) to complete the City 2™ paver installation. Pavers can be a maximum
of 3” thick. Pavers must be mechanically attached to the concrete pad using a setting material
(such as mortar or thinset for example) that is no thicker than 3/8”.
1” of each 3/8” x 7” wedge anchor (18 ea.) needs to be exposed above the final deck surface.
The 3/8” wedge anchors must be drilled to a depth of 6” with 1” of the bolt left remaining above
the final deck surface. The 3/8” x 7” wedge anchors (16 ea.) replace the 5/16” lag bolts and
lag shields (16 ea.) included with the required CITY-DECK ANCHOR parts (4 ea.), one set per leg.
See Figure 3. The remaining 3/8” x 7” wedge anchors (2 ea.) are used (1 per side) to attach the
ladder bottom to the concrete pad and replace the 1/4” x 2-1/4” wedge anchors (4 ea.) from
hardware kit CS-101-SS.
The ladder bottom must have the forward 1/4” hole on each side (toward slide) drilled to 1/2” to
accommodate the 3/8” x 7” wedge anchor. The rear 1/4” holes on the ladder bottom are not
used with the paver installation. See Figure 4. You will need to factor in the thickness of your paver
(3” MAX.) and the thickness of your setting material (3/8” MAX.) for your individual installation.
You will need a 3/8” masonry bit and a 1/2” regular bit for the City 2™ slide.
Inter-Fab Inc. will not be responsible for damage to pavers caused by drilling or mechanically
attaching to concrete pad. Refer to paver manufacturer’s specific installation instructions
before beginning.
Fig. 2
Example of Deck Anchor on Concrete Pad
(Side View)
CONCRETE
12” min.
Layer of setting
material to
secure pavers
to concrete.
PAVERS
3”
max.
Drawing Is
NOT To Scale
HEIGHT OF WEDGE
ANCHOR ABOVE
FINAL DECK
SURFACE
WEDGE
ANCHORS
16” min.
5” min.
from edge
DECK ANCHOR
PAVER KIT INFO – CITY 2 SLIDE